INPUT BOARD VOLTAGE TEST (continued)
J2: Input/Control connector
Pin#
Description
1
+15V
2
SGND
• 0Vdc=Water flow OK
3
FLOW
• 15Vdc= Water flow KO (Err 11 on display)
• 2Vdc=150A – 3,6Vdc=270A for 315DC
4
MIS_I
• 1Vdc=100A – 4Vdc=400A for 415DC
• 6Vdc +/- 10% in stick mode in OCV
condition
5
MIS_V
• 0,6 Vdc +/- 10% TIG modes in OCV
condition
• 0V= in stick mode
6
HFON-PK
• 7,5Vdc +/- 10% in LIFT and HF mode
• +12Vdc +/- 10% in Lift TIG mode, stand-by
condition (no OCV, no fan), thermal and
any overload condition.
7
VREG
• 0,6Vdc +/- 10% in stick mode during OCV
condition for 315DC
• 0,4Vdc in stick mode during OCV condition
for 415DC
• +15Vdc in Stick and Lift TIG mode
8
HVPON
• 0Vdc in TIG HF mode
• +5Vdc only during Power Up sequence
9
READY_OK
• 0V during normal operation condition
• +15Vdc in Stick mode
10
COOLER
• 0V in both TIG modes
• 0V=normal value
11
TH1
• 15Vdc +/- 10% = thermic activated on
inverter board
• For 315DC:
50A=1Vdc_150A=3Vdc_300A=6Vdc
12
DUTY
• For 415DC:
50A=0,75Vdc_150A=2,2Vdc_400A=6Vdc
13
LS
23Vdc +/- 10% in OCV condition
14
ILIM
• 0V=normal value
15
TH2
• 15Vdc +/- 10% = thermic activated on
output board
• 13Vdc +/- 10% any modes in stand-by
16
/TR
• 0Vdc = trigger pushed
• 24Vdc +/- 10% = gas solenoid OFF
17
SOL
• 0Vdc = Gas solenoid ON
• 0V=HF OFF
18
HF
• 15Vdc +/- 10% = HF ON (only for 3
seconds after trigger pushed)
19
SGND
20
300/400
0Vdc=300A
• +24Vdc +/- 10% = FAN OFF
21
FAN
• 0Vdc = FAN ON
22
FAN DRIVE
• +5Vdc +/- 10% with FAN OFF
23
FAN SPEED
• 0Vdc with FAN ON
24
VRIF
Value (use SGND as 0V ref.)
+15Vdc
SGND
Not Used
SGND
5Vdc +/- 10% =400A
+5V any condition
Not Used
Notes
+15Vdc generated by input board
Secondary GND for power supply (0V ref.)
Water flow signal from coolarc->input board
Output current feedback
Output voltage feedback
Signal for starting peak current in HF
(visible only with oscilloscope)
+12Vdc = inverter OFF
Only when in TIG HF mode +15Vdc are applied
to
pin 1 of HF connector
Cooler ON/OFF
Thermostat on the inverter heat sink signal
Output current set signal
Lift TIG mode detection signal
Not Used
Thermostat on the output heat sink signal
Trigger signal
Gas solenoid ON/OFF
HF ON/OFF
Control board machine identification
FAN ON/OFF
Not used
45