At+Linkslave Slave Max Link Quantity; At+Uuidsvr128 Set 128-Bit Uuid - Ebyte E104-BT5032A/B User Manual

Nrf52832 ble5.0 low power ble to serial module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd
1. Take effect immediately, save after power off.
2. If 4 devices are currently connected, but 2 are set at this time, the master will not
Remarks
disconnect the connected devices.
3. The instruction supports firmware version: V1.1.
4. The number of connections is limited to automatic connections only.
AT+LINKSLAVE
7.4.39
AT+LINKSLAVE?
Query
AT+ LINKSLAVE =[para]
Set
para(ASCCII): max link quantity. range:1~4
Parameter
Dafault:4
1. Take effect immediately, save after power off.
2. If 4 devices are currently connected, but 2 are set at this time, the slave will not disconnect the connected
Remarks
devices.
3. The instruction supports firmware version: V1.1.
4. The number of connections is limited to automatic connections only.

7.4.40 AT+UUIDSVR128 set 128-bit UUID

Query
AT+UUIDSVR128?
Set
AT+ UUIDSVR128=[para]
Parameter
para(HEX):16-bit uuid.
1、 take into effect after reset and save when power off。
2、 the 2,3byte is 16-bit uuid, ranging from 1~65535;
Remarks
3、 128-bit UUID,except for 2,3byte, are used for the slave, the master and configuration channel.(Check
details about uuid from《BLUETOOTH SPECIFICATION Version 5.0 | Vol 3, Part B 2.5.1 UUID》).
Set 128-bit UUID:
"11 22 33 44 55 66 77 88 99 00 aa bb cc dd ee ff"(HEX)
For example
AT command is (HEX):
61 74 2b 75 75 69 64 73 76 72 31 32 38 3d 11 22 33 44 55 66 77 88 99 00 aa bb cc dd ee ff
Copyright ©2012–2024,Chengdu Ebyte Electronic Technology Co., Ltd
Slave max link quantity
command
command
respond
+OK=[para]
+OK:success
+ERR=[NUM]:error
respond
+OK=[para]
+OK:success
+ERR=[NUM]:error