Data Transmission; Data Transparent Transmission - Ebyte E104-BT5032A/B User Manual

Nrf52832 ble5.0 low power ble to serial module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd
Refer to 6.4 command list to configure the module;

8.2 Data transmission

Please refer to 5.3 data transmission mode for details.
Test condition:
Refer to 7.1, set one module as the master and the other one as the slave;
Test software:SSCOM;
Other parameters are as default.
8.2.1

Data transparent transmission

1.
Once powered on, the master and the slave enable logmsg to print(at+logmsg=1);
2.
Set module as transparent transmission mode(AT+TRANMD=1);
3.
Once connected , the master prints "STA:connect,0,619AA43CBAF3"; the slave prints "STA:connected". LINK pin is low.
Please refer to figure below. From master's printing info, the value before the MAC address is sentences from the slave, where the first
byte of format transmission comes.
Copyright ©2012–2024,Chengdu Ebyte Electronic Technology Co., Ltd
Authentication of configuration over air
Automatically connect and print once the master is powered on
E104-BT5032A User Manual