At+Discon Disconnect Command; At+Datdly Data Output Delay - Ebyte E104-BT5032A/B User Manual

Nrf52832 ble5.0 low power ble to serial module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd
parameter modification is successful. During the negotiation process between the master and the slave, if
the other device refuses to modify, the connection can only be made according to the connection parameters
of the other device.
7、 This command is good for firmware:V1.1
AT+CONPARAMSx=2,16,0,400
For example
Connection interval 16*1.25ms, the delay of salve:0,16*1.25ms,connection timeout 400*1.25ms

7.4.24 AT+DISCON disconnect command

Set
AT+DISCON=[
(only for master)
Disconnect all
AT+DISCON
Parameter
1 Take into effect immediately.
2 As slave, only disconnect all is available;
3 Disconnect all is available for master and slave mode;
Remark
4 If handle specified connection is not connected, the module will return error;
5 For Handle please refer to 6.10 multilink.

7.4.25 AT+DATDLY Data output delay

Query
AT+DATDLY?
AT+DATDLY=[para]
Set
Parameter
1 Take into effect immediately, save when power off
Remarks
2 Turn on the output delay, the maximum packet size does not exceed 244 bytes;
3 Turn on the output delay. If the air packet input is too fast, the entire packet will be lost.
Copyright ©2012–2024,Chengdu Ebyte Electronic Technology Co., Ltd
command
handle
]
handle(ASCII)
0~7
command
para(ASCII)
0
1
respond
+OK:success
+ERR=[NUM]:error
+OK:success
+ERR=[NUM]:error
description
Disconnect specified connection
respond
+OK=[para]
+OK:success
+ERR=[NUM]:error
description
close
enable(default)
E104-BT5032A User Manual
31

Advertisement

Table of Contents
loading

Table of Contents