Quick Links

SYSTEM Inverter Air Conditioners
MODELS
Ceiling-mounted cassette type (corner model)
FXKQ25MVE
FXKQ32MVE
FXKQ40MVE
FXKQ63MVE
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG FÜR SPÄTERE BEZUGNAHME GRIFFBEREIT AUF.
LIRE SOIGNEUSEMENT CES INSTRUCTIONS AVANT L'INSTALLATION.
CONSERVER CE MANUEL A PORTEE DE MAIN POUR REFERENCE ULTERIEURE.
LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR.
GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER
ALGUNA DUDA.
PRIMA DELL'INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI.
TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI.
ÄΙΑΒΑΣΤΕ ΠΡΟΣΕΚΤΙΚΑ ΑΥΤΕΣ ΤΙΣ ΟÄΗΓΙΕΣ ΠΡΙΝ ΑΠΟ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΕΧΕΤΕ ΑΥΤΟ
ΤΟ ΕΓΧΕΙΡΙÄΙΟ ΕΥΚΑΙΡΟ ΓΙΑ ΝΑ ΤΟ ΣΥΜΒΟΥΛΕΥΕΣΤΕ ΣΤΟ ΜΕΛΛΟΝ.
LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE. BEWAAR DEZE HAN-
DLEINDING WAAR U HEM KUNT TERUGVINDEN VOOR LATERE NASLAG.
LEIA COM ATENÇÃO ESTAS INSTRUÇÕES ANTES DE REALIZAR A INSTALAÇÃO.
MANTENHA ESTE MANUAL AO SEU ALCANCE PARA FUTURAS CONSULTAS.
ПЕРЕД НАЧАЛОМ МОНТАЖА ВНИМАТЕЛЬНО ОЗНАКОМЬТЕСЬ С ДАННЫМИ
ИНСТРУКЦИЯМИ. СОХРАНИТЕ ДАННОЕ РУКОВОДСТВО В МЕСТЕ, УДОБНОМ ДЛЯ
ОБРАЩЕНИЯ В БУДУЩЕМ.

INSTALLATION MANUAL

English
Deutsch
Français
Español
Italiano
ΕλληνικÜ
Nederlands
Portugues
Russian
Taiwanese
Chinese

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FXKQ25MVE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin FXKQ25MVE

  • Page 1: Installation Manual

    INSTALLATION MANUAL English SYSTEM Inverter Air Conditioners Deutsch MODELS Français Ceiling-mounted cassette type (corner model) FXKQ25MVE Español FXKQ32MVE FXKQ40MVE FXKQ63MVE Italiano READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. ΕλληνικÜ LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
  • Page 2 *Σηìεßωση *Nota tal como estabelecido no Ficheiro Técnico de Construção DAIKIN.TCF.022 e com o parecer positivo de NMi de acordo com o Certificado 0301130401. *Bemærk som anført i den Tekniske Konstruktionsfil DAIKIN.TCF.022 og positivt vurderet af NMi i henhold til Certifikat 0301130401.
  • Page 3: Table Of Contents

    VRV SYSTEM Inverter Air Conditioners Installation manual CONTENTS Improper installation work may result in the equipment falling and causing accidents. 1. SAFETY CONSIDERATIONS.......... 1 • Make sure that a separate power supply circuit is provided for 2. BEFORE INSTALLATION ..........2 this unit and that all electrical work is carried out by qualified personnel according to local laws and regulations and this 3.
  • Page 4: Before Installation

    BEFORE INSTALLATION Insulation for Insulation for • When moving the unit while removing it from the carton Name Sealing pad hanger fitting bracket box, be sure to lift it by holding on to the four lifting lugs without exerting any pressure on other parts, especially, Quantity 1 each.
  • Page 5: Selecting Installation Site

    FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE • Where sufficient clearance for installation and mainte- nance can be ensured. DURING CONSTRUCTION AND CHECK AFTER • Where there is no risk of flammable gas leakage. INSTALLATION IS FINISHED. • Where piping between indoor and outdoor units is possi- ble within the allowable limit.
  • Page 6: Indoor Unit Installation

    Model Positioning jig for installation 1 (accessory) FXKQ25 · 32 · 40MVE 1110 1150 1200 1240 Positioning FXKQ63MVE 1310 1350 1400 1440 jig for installation 2 (2) Open a hole in the ceiling for installation. (Case of existing Positioning jig for accessory ceiling) installation 2...
  • Page 7 (When using a heat pump, the temperature of the gas piping • Wrap the sealing pad (accessory) only around the insulation can reach up to approximately 120°C, so use insulation which is for the joints on the gas piping side. sufficiently resistant.) Clamp 〈...
  • Page 8: Drain Piping Work

    • Wrap the sealing pad over the clamp and drain hose to Not recommendable but in case of emergency insulate. You must use a torque wrench but if you are obliged to install the • Insulate the drain hose inside the building. unit without a torque wrench, you may follow the installation While referring to the figure on the right, insulate the method mentioned below.
  • Page 9: Electric Wiring Work

    Be sure attach the electric parts box lid before turning on the ELECTRICAL CHARACTERISTICS powe. Power Next, press the inspection/test operation button “ ” on the Units Fan motor TEST supply remote controller. The unit will engage the test operation mode. Voltage Model Volts...
  • Page 10 [ PRECAUTIONS ] NOTE 1: Details of terminal block for power supply 1. Use round crimp-style terminals for connecting wires to the Electric parts box power supply terminal board. If unavailable, observe the following points when wiring. • Do not connect wires of different gauge to the same power supply terminal.
  • Page 11 HIGH CEILING INSTALLATION WIRING EXAMPLE (1) This unit can be installed in ceilings up to 3.8 meters high. • Fit the power supply wiring of each unit with a switch and fuse If the ceiling height exceeds 2.7 meters, however, connect as shown in the drawing.
  • Page 12 3. When including BS unit Wiring Method (See “ELECTRIC WIRING WORK”) (3) Remove the electric parts box lid. (4) Add remote control 2 (slave) to the terminal block for Power Power Outdoor unit supply supply remote controller (P ) in the electric parts box. 220-240V 220-240V Control box...
  • Page 13: Decoration Panel Installation

    10. DECORATION PANEL INSTALLATION 12. TEST OPERATION Refer to the installation manual of the panels. Refer to the installation manual of the outdoor unit. • The operation lamp of the remote controller will flash when [ PRECAUTIONS ] an malfunction occurs. Check the malfunction code on the liquid crystal display to identify the point of trouble.
  • Page 14 3P086156-8J EM02A082A (0303) HT...