Installation Manual; In General; Chimney - RAIS JUNO 120 L Manual

Table of Contents

Advertisement

INSTALLATION MANUAL

Thank you for choosing your new RAIS
product! This installation manual will
ensure that your fireplace insert is in-
stalled correctly and that it will provide
you with comfort and pleasure for many
years to come.

IN GENERAL

It is important to correctly install the
stove out of consideration for both the
environment and personal safety. The
installation of the stove must comply
with all local rules and regulations, in-
cluding those that refer to national and
European standards. A certified chim-
ney sweeper should be contacted be-
fore the installation is started.
No unauthorised alterations may be
made to the stove.
GENERAL
INSTALLATION
MENTS
Before the stove may be put to use, the
installation must be reported to your lo-
cal chimney sweeper.
There must be a plentiful supply of fresh
air in the installation room to ensure
good combustion – if required, through
an Air-System connection. NB: Any me-
chanical air extraction, for example a
cooker hood, can minimise the supply
of air.
The wood-burning stove has an air con-
sumption of at least 13 m3/h.
The floor structure must be able to sup-
port the weight of the wood-burning
stove and a chimney. If the existing floor
structure does not meet this require-
ment, suitable measures must be taken
(e.g. installation of a load distribution
plate). Seek advice from a building ex-
pert.
If the wood-burning stove is to be in-
4
INSTALLATION MANUAL
stalled on a flammable floor, national
and local regulations must be com-
plied with, including for the size of the
non-flammable plate, which must cover
the floor in front of the wood-burning
stove to protect the floor from any em-
bers that fall out of the stove.
The stove must be positioned at a safe
distance from flammable material. Due
to risk of fire, flammable items (e.g. fur-
niture) may not be positioned closer to
the stove than the closest permitted
distance stated in the installation sec-
tion. When deciding where to install
your RAIS/ATTIKA stove, you should
think about being able to heat other
rooms in the home, so you get the most
out of your new stove.
After receiving your stove, please check
it for any defects.
REQUIRE-

CHIMNEY

The chimney must be tall enough to
ensure correct draught conditions,
i.e. -12 to -18 pascal. If the recom-
mended
be achieved, problems from smoke
escaping from the door may arise
when lighting the fire. We recommend
adapting the chimney to suit the flue
outlet connector. The flue outlet con-
nector is 150 mm in diameter.
If the draught is excessive, it is recom-
mended that you equip the chimney
with a regulating damper. If a regulating
damper is fitted, you must ensure that
there is a free flow area of at least 20
cm² at the closed regulating damper.
Remember that there must be unob-
structed access to the access door on
the chimney.
chimney
draught
cannot

Advertisement

Table of Contents
loading

This manual is also suitable for:

Juno 160 l