Thermistor
USER GUIDE
Thermistors are used for various temperature readings.
Thermistors provide reliable temperature readings
using a resistance which varies based on surrounding
Thermistor
temperatures. If a faulty thermistor is suspected it may be
tested using an accurate ohmmeter.
Thermistors are used for various temperature readings.
Thermistors provide reliable temperature readings using a
All the thermistors in the unit are identical. If a thermistor
resistance which varies based on surrounding temperatures. If a
is suspected of being defective, the resistance can be
faulty thermistor is suspected, it may be tested using an
verified. Place the thermistor in an ice water bath, the
accurate ohmmeter.
resistance should read 16.1k Ohms +/-5% on your meter.
Thermistor connections must be kept clean. A thermistor
Thermistor connections must be kept clean. A thermistor
connection that has become corroded can cause resistance
connection that has become corroded can cause resistance
values from the thermistor to change as they pass through a
values from the thermistor to change as they pass through
dirty connection to the board.
a dirty connection to the board.
It is for that reason that we apply dielectric grease to all of our
It is for that reason that we apply dielectric grease to all of
thermistor connections. Dielectric grease will help to keep
our thermistor connections. Dielectric grease will help to
thermistor connections clean and dry.
keep thermistor connections clean and dry.
If you change a thermistor in the unit, please re-apply dielectric
If you change a thermistor in the unit please re-apply
grease to the connection. If you encounter a dirty thermistor
dielectric grease to the connection. If you encounter
connection, you should replace the thermistor and the
a dirty thermistor connection, you should replace the
thermistor harness.
thermistor and the thermistor harness.
This unit has one thermistor located along the right hand
sidewall of the ice bin. It is used to maintain the ice level in the
Thermistor error information can be found in the Control
bin.
Operation - Service section.
This unit has four thermistors.
Thermistor One (Top Zone):
Located along the side wall in the upper zone. It is used to
maintain the operating temperature within that zone.
Thermistor Two (Top Evaporator)
Located on the top evaporator - used for defrost.
Thermistor Three (Bottom Zone):
Located along the side wall in the bottom zone. It is used
to maintain the operating temperature within that zone.
Thermistor Four (Bottom Evaporator)
Located on the bottom evaporator - used for defrost.

THERMISTOR FAILURE

Zone Thermistor
If a zone thermistor in the unit fails, the unit will continue
to cool in a backup mode (Self Preservation Mode) to
preserve the integrity of the contents. The unit will
otherwise operate normally.
Thermistor

Evaporator Thermistor

If an evaporator thermistor fails, the unit will rely on a
preset defrost timer during defrost cycles. The unit will
otherwise operate normally. Refer to defrost section.
Thermistor Resistance Data
Thermistor Resistance Data
Temp (F)
Temp (C)
-40
-40
-31
-35
-22
-30
-13
-25
-4
-20
5
-15
14
-10
23
-5
32
0
41
5
50
10
59
15
68
20
77
25
86
30
95
35
104
40
113
45
122
50
131
55
140
60
149
65
158
70
167
75
176
80
-
* (+/
5%)
36
u-line.com
Nominal Resistance
(OHMS)*
169157
121795
88766
65333
48614
36503
27681
21166
16330
12696
9951
7855
6246
5000
4029
3266
2665
2186
1803
1495
1247
1044
879
743
631