Checking Product Temperature - Viking VCWD630-SG41A User Manual & Service Manual

Table of Contents

Advertisement

USER GUIDE
Problem
Possible Cause and Remedy
Product is Not Cold
Air temperature does not indicate product
Enough
temperature. See CHECKING PRODUCT
TEMPERATURE below.
Adjust the temperature to a cooler set
point.
Ensure unit is not located in excessive
ambient temperatures or in direct
sunlight.
Ensure the door is closing and sealing
properly.
Ensure the interior light has not
remained on too long.
Ensure nothing is blocking the front
grille, found at the bottom of the unit.
Ensure the condenser coil is clean and
free of any dirt or lint build-up.

CHECKING PRODUCT TEMPERATURE

To check the actual product temperature in the unit:
1.
Partially fill a plastic (nonbreakable) bottle with water.
2.
Insert an accurate thermometer.
3.
Tighten the bottle cap securely.
4.
Place the bottle in the desired area for 24 hours.
5.
Avoid opening the unit during the testing period.
6.
After 24 hours, check the temperature of the water.
If required, adjust the temperature control in a small
increment (see CONTROL OPERATION).
Causes which affect the internal temperatures of the
cabinet include:
Temperature setting.
Ambient temperature where installed.
Installation in direct sunlight or near a heat source.
The number of door openings and the time the door is
open.
The time the internal light is illuminated. (This mainly
affects product on the top rack or shelf.)
Obstruction of front grille or condenser.
Troubleshooting