USER GUIDE
SERVICE MODE GUIDE
0. Exit
1. Thermistor 1 temperature not including offsets.
2. Thermistor 2 temperature not including offsets.
3. Thermistor 3 temperature not including offsets.
4. Thermistor 4 temperature not including offsets.
5. Thermistor 1 offset. (+/- 10)
6. Thermistor 2 offset. (+/- 10)
7. Thermistor 3 offset. (+/- 10)
8. Thermistor 4 offset. (+/- 10)
9. Thermistor 2 set point
10. Thermistor 3 set point.
11. Thermistor 4 set point.
12. Defrost Interval (0 to 99 hr)
13. Defrost duration (0 to 99 min)
14. Error Log (See Appx D)
15. Clear error log (hold light key until cleared)
16. Thermistor 1 differential (+5)
17. Thermistor 3 differential (+5)
18. Evaporator fan on delay (0 to 99 sec)
19. Evaporator fan off delay (0 to 99 sec)
20. Individual component toggle
- Option #0 – Exit
- Option #1 – Relay 1
- Option #2 – Relay 2
- Option #3 – Relay 3
- Option #4 – Relay 4
- Option #5 – Relay 5
- Option #6 – Relay 6
- Option #7 – DC Output 1
- Option #8 – DC Output 2
- Option #9 – DC Output 3
- Option #10 – DC Output 4
- Option #11 – DC Output 5
- Option #12 – Serial output (Compressor)
21. Model number
22. Light All Segments
23. Activate Defrost/Harvest- press and hold for 3 seconds
to activate defrost/harvest
24. Defaults- press and hold for 3 seconds to restore all
values to factory defaults.
25. Main Software (Display only)
26. Live Log Period (frequency that data is output to
diagnostics port)
27. Factory test mode (0=Off, 1=On)
28. Compressor RPM
29. Freeze time adjust (Model 54 only)
30. Harvest time adjust (Model 54 only)
31. Low temp alarm limit (Model 55 only)
32. High temp alarm limit (Model 55 only)
Control Operation-Service
SERVICE MODE GUIDE
1.
THERMISTOR 1 - TOP ZONE
This shows the pure thermistor reading with no
offsets taken into account.
2.
THERMISTOR 2 - TOP EVAPORATOR
This shows the pure thermistor reading with no
offsets taken into account.
3.
THERMISTOR 3 - BOTTOM ZONE
This shows the pure thermistor reading with no
offsets taken into account.
4.
THERMISTOR 4 - BOTTOM EVAPORATOR
This shows the pure thermistor reading with no
offsets taken into account.
5.
THERMISTOR 1 - TOP ZONE OFFSET
(DO NOT MAKE AN ADJUSTMENT TO THIS WITHOUT
CONTACTING TECH LINE) This calibration is only to
be used if actual temperature at thermistor #1 is off
from set point. By adjusting the offset higher, we can
force the unit to drive the temperaturee down below
the set point. (example: adjusting from 0 to +2 will
drop the unit temperature 2 degrees)
6.
THERMISTOR 2 - TOP EVAPORATOR OFFSET
This shows the pure thermistor reading with no
offsets taken into account.
7.
THERMISTOR 3 - BOTTOM ZONE OFFSET
(DO NOT MAKE AN ADJUSTMENT TO THIS WITHOUT
CONTACTING TECH LINE)
8.
THERMISTOR 4 - BOT. EVAPORATOR OFFSET
This shows the pure thermistor reading with no
offsets taken into account.
9.
THERMISTOR 2 - SET POINT MINUS OFFSET
This shows the pure thermistor reading with offsets
taken into account.
10. THERMISTOR 3 - SET POINT MINUS OFFSET
This shows the pure thermistor reading with offsets
taken into account.
11. THERMISTOR 4 - SET POINT MINUS OFFSET
This shows the pure thermistor reading with offsets
taken into account.
12. ADJUST DEFROST INTERVAL: 1-12 HOURS
This will adjust the interval between defrosts from
1-12 hours. Adjusting from the factory settings may
cause undesired temperature.
13. ADJUST DEFROST DURATION: 5-99 MINUTES
The length of the defrost can be adjusted 5-99
minutes long. the other defrost parameters still
apply. Lengthening a defrost may cause higher than
normal temperatures.