Summary of Contents for Vari Lite Strand Leko LED Profile Tunable Warm White
Page 1
Leko LeD ProfiLe TunabLe Warm WhiTe User ManUal...
Page 2
COMPOnenTs The document provides installation and operation instructions for the following products: • Strand Leko LED Profile Tunable Warm White Read all instructions before installing or using this product. Retain this manual for future reference. Additional product information and descriptions may be found on the product specification sheet.
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL 2 InsTallaTIOn MOUnTInG The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight.
Page 4
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL TABLE 1. MENU FUNCTIONS leVel 1 leVel 2 leVel 3 leVel 4 leVel 5 leVel 6 DeFaUlT address 001~512 (Default 001) leD Hours XXXXXX h reset leD Hour are you sure? square Curve (Default) Dimming Curve s Curve...
Page 5
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL TABLE 1. MENU FUNCTIONS leVel 1 leVel 2 leVel 3 leVel 4 leVel 5 leVel 6 DeFaUlT address 001~512 ssCC (Default) DMX Mode sQCC sOCC Group 1 (Default) Pixel Group Group 3 Group 12 normal (Default) Cell Direction...
Page 6
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL aDDress MenU Address — DMX address setting. To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN button to adjust the address from 001 to 512, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode.
Page 7
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL Normal or Flipped, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode. Data — To select Data, press the ENTER button to confirm. Use the UP/DOWN button to select Ch1 – Intensity xxx(value), Ch2 –...
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL 3 DMX MaPPInG The fixture can be operated by DMX controller. The following tables assumes a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in se- quence.
Page 10
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL TABLE 3. 8-BIT MODE ParaMeTer DeFaUlTs ranGe DMX DesCrIPTIOn CHannel lamp controls, and miscellaneous modes. set discrete value of desired effect, wait >3 seconds, then set value to 0 (Idle). **Function does not require 3 second rule to active, setting output to value will automatically activate function 0 - 5 Idle (Default)
Page 11
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL TABLE 4. 2 CHANNEL MODE ParaMeTer DeFaUlTs ranGe DMX DesCrIPTIOn CHannel 8 bit Intensity (Dimmer) Control Intensity 0 - 255 0 - 100% Output TW leD 0 - 255 Tunable leD array 0 - 100% 0 = 2700K 100% = 4500K TABLE 5. CONTROL CHANNEL...
Page 12
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL TABLE 5. CONTROL CHANNEL ranGe POWer CYCle FUnCTIOn ITeMs DesCrIPTIOn rUles seleCTIOn VIa UI 86 - 90 reserved Values Holds setting on 91 - 95 reserved Values power cycle Holds setting on 96 - 100 reserved Values power cycle 101 - 105...
Page 13
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL LINEAR S-CURVE SQUARE LAW DMX OUTPUT DMX OUTPUT DMX OUTPUT KnOB 1 KnOB 2 KnOB 3 1.DIM 2.CCT 3.G shift Full Color KnOB MODe MODe 0-100% 1800K-10000K -99% - 99% note: Double click Dial 1 to Dial MODe W W W.Va r i - L i T e .C o m...
Page 14
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL DMX512 COnneCTIOn • At last unit, the DMX cable has to be terminated with a terminator. Solder a 120Ω 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 5-pin XLR-plug and plug it in the DMX-output of the last unit. •...
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL aPPenDIX a Care anD MaInTenanCe TrOUBlesHOOTInG Following are a few common problems that may occur during operation. The unit does not work - light and fan do not turn on • Check the connection of power and main fuse. •...
Page 16
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL ADDENDUM Fan Speed and Control All Vari-lite and Strand lighting luminaires will be governed by the same Fan speed v Noise levels v Maximum power output rules as details below. These noises related to these levels will confirm to Noise Criteria levels details of NC 55 NC 55 which are contained within the document.
Leko LeD ProfiLe TunabLe Warm WhiTe user manuaL HOW TO OBTaIn WarranTY serVICe A copy of the Strand Limited Warranty was included in the shipping package for this Strand product. entertainment.service@ To obtain warranty service, please contact customer service at 1-214-647-7880, or signify.com and request a Return Material Authorization (RMA) for warranty service.