Hardware Manual
Chapter 2: Installation and Configuration
This section provides information concerning the installation and wiring of the UFM-ST filter. Wiring
information includes wire size and insulation requirements. Refer to other product documentation
for additional installation requirements
2.1. AC Power Connections
The UFM-ST has two AC connectors; an Input connector (AC Mains) and an Output connector (Load).
Each of these connectors also has a ground terminal.
WARNING: The System Integrator or end user is responsible for determining and
meeting all safety and compliance requirements necessary to integrate the UFM-ST into
the final application.
2.1.1. AC Input Power Wiring
The UFM-ST three-terminal input connector is the AC power (Mains) connector. The AC1 and AC2
terminals are the AC power lines (Internally fused at 10 Amps). The Ground terminal is connected
internally to the external Ground Stud and must be connected to Ground.
Wiring to the UFM-ST filter must use #16 AWG wires or larger and have an insulation rating of at
least 300 V.
DANGER: Ground connection must be connected to ground to minimize possibility of
electrical shock hazard.
Figure 2-1:
AC Input Connections
www.aerotech.com
UFM-ST
19