11. PRINTER FUNCTIONS
MELSEC-A
(3) Designating the number of outputs
The following explains the method and gives an example of the desig-
nation of the number of pieces of output data that is continuously output
from the schedule position designated by setting an output pointer.
Desianation methodl
The
set value is the number of
continuous outputs.
I
An error will occur if the sum of the number of output pointers and the
number of outputs exceeds 100.
I
To output data from the 10th schedule area to the printer (AlSJ71C24-PRF
1 1 0
addresses:
20H to 3FH).
I
(Sequence program)
'50'
i s
written to buffer address 822H.