Quick Links

Exit program, cancel call
Save program
00
Change master code (0000
is default)
Add new forwarding tenant's
01
directory
Edit existing tenant's
02
directory
Delete existing tenant's
03
directory
Clear all forwarding tenant's
04
directory
05
Enable/Disable Call
06
New access code
07
Delete access code
08
Clear all access code
09
Access code digit (4-8 digit).
Default is 4-digit
10
Add new card
11
Delete card
12
Clear all card
13
Set time
14
Set date
15
Initializing event recording
16
AUS= auto unlock schedule
(0-9 schedule)
17
TMZ= time zone. 20 TMZ,
00-20.
18
HLD= holiday zone. 20 HLD,
1-20
19
Directory digit (2-4 digit).
Default is 2-digit
20
AUXIN1
0= disable (default)
1= enable control by relay 1
open interval
2= relay 1 control by AuxIn2
21
AUXIN2
0= disable (default)
1= enable control by relay 2
open interval
2= relay 2 control by AuxIn2
22
Do not disturb
0= disable (default),
1= enable
23
Lock-out Count
24
Alarm
0= disable
1= local beep for 60
seconds
2= disable system for 60
seconds with no beep
3= call directory (0-9)
25
Keypad beep
0= disable (default)
1=enable
26
Door beep
0= disable
1= enable (default)
27
Talk time (060-240
second). Default=60
second
28
Unlock relay1 time
(12-99 second).
Default= 12 second
29
Unlock relay2 time
(12-99 second).
Default= 12 second
33
Temporary code
34
Special code
35
Temporary card
36
Special card
38
System acknowledge
(0-9). Default= 3
39
Remote access
0= disable
1=enable (default)
40
DTMF relay 1 (0-9).
Default=9
41
DTMF relay 2 (0-9).
Default=8
42
Relay 2 Mode
1= door control (default)
2= relay 2 trigger
simultaneously as relay
1
3= enable if function
code 24 is enable
4= turn relay 2 on and
off
On=7, Off=6
43
DND: do not disturb time
zone (0-9)
44
Disable Time zone relay
1, 2 or both
45
Relay 1 and 2 unlock
timer
46
Firmware version
48
PBX enable. Default=
disable
49
Edit Access code
50
Erase the memory to
factory default
51
Welcome screen
24 Months warranty
for complete system
6 Months warranty
for Printed Circuit Board
Log on to programming:
Press
release, the welcome message will
stop scrolling (repeat if screen still
scrolling) enter 4-digit
CODE" (0000 is default), the screen
will show as below:
Select the
the table
OPERATION
Two ways to call tenant
1. Press
to scroll name from A-Z or
from Z-A then press
2. Press
wait for dial tone then press the directory
number
Opening the door remotely
(relay 2)
Open the door with the access code
screen will stop scrolling) then press a valid 4-digit access
code.
Extend talk time
tenant must press
after the time out warning beep.
Call into the
system:
1. Enable function code 39 and function code 38 must be
set 1-9
2. Call the system phone number, hear one beep if the
system
answering the call.
3. Press
then 4-digit master code, hear one short
beep
4. Press
to establish two way communication
5. Press
or
to release the door.
.
QWCM iP BROWSER DEFAULT IP
IP: 192.168.1.230
SUBNET: 255.255.255.0
GATEWAY: 192.168.1.1
DNS: 192.168.1.1
USERNAME: Administrator
PASSWORD: 8888 / pach
simultaneously then
"MASTER
"Function
Code" from
to scroll name
to call name selected.
press
(relay 1) or
press
(display
from the phone

Advertisement

loading

Summary of Contents for PACH & COMPANY QUANTUM QC6IPFF

  • Page 1 Exit program, cancel call Lock-out Count Save program Alarm 0= disable 1= local beep for 60 seconds 2= disable system for 60 seconds with no beep 3= call directory (0-9) Change master code (0000 Keypad beep is default) 0= disable (default) 1=enable Add new forwarding tenant’s Door beep...
  • Page 2 Technical Support is available Monday-Friday 7:00 am-4:00 pm PST at 1-888-678-7224 Technical Info and complete manual are available online www.pach-co.com INPUT POWER 12VAC 40VA SUPPLIED (voltage measurement must be 12.5-14.0 VAC) OR 12VDC 2A adjustable power supply (voltage measurement must be 13.5-14.0 VDC) 12 VDC 4Ahr BATTERY BACK-UP (OPTIONAL) WARNING: THIS IS NOT INPUT POWER...

This manual is also suitable for:

Quantum qc seriesQuantum qc1ipQuantum qc2ipQuantum qc1ipffQuantum qc2ipffQuantum qc6ip