Maintenance

All cardio machines from emotion fitness are characterized by excellent quality. The units are durable and only
need little maintenance, to function over a long period of time. The required maintenance hast to get
conducted conscientious.
Warning: Only authorised service is allowed to open the unit.
You can only keep the safety level by checking the unit regularly for damage and attrition. Damaged parts need
to get replaced right away and the unit needs to get decommissioned until its repair.
5.1

Instructions for the error condition detection (failure)

In case failure occurs at a machine that you cannot classify, please contact emotion fitness GmbH & Co. KG. For
every error report please hold ready the serial number and model type of the faulty machine. It can be
important to diagnose properly and to provide the correct spare parts!
5.2

Instructions for preventive maintenance by the operator

Check the unit visually before every usage but at least daily particularly for damaged parts, loose connections
and atypical noises.
Despite an excellent quality management system the unit has to get inspected intensely every six months.
Document the inspection for medical machines in the medical booklet:
Check all connections and welding seams.
Clean the unit well.
Check all screws for tightness.
Check the saddle and saddle pole for damages. Beware to exchange the saddle every 2 years to
prevent fatigue of the material.
Check the cranks and pedals for damages and tightness.
In general:
Clean the devices with mild purifier and a wet cloth to get off aggressive sweat. Dry the device
afterwards.
The usage of spray bottles is not allowed; it has shown that the unit never dries at spots that can´t be
reached. Rust may occur.
Pay attention that no liquids run into the monitor as it could destroy parts of the electronic.
If disinfection is required only use acryl-des® disinfection cloths (see http://www.schuelke.com/).
The monitor is showing the sign for low battery voltage when the function without electricity from
the brake can´t be guaranteed. Exchange the three AA batteries by removing the four screws of the
monitor casing and take away the front carefully. Please pay attention that you put the batteries in
the right way, note the signing. Dispose the batteries according to the provisions. There is a return
obligation; the customer can choose if he wants to give the batteries to the local disposer or to the
distributor free of charge.
Beware to not put the machines on thick rubber mats where the frame gets pushed in. The bottom
of the frame needs to get ventilated.
Check the casing for tightness.
Check the locking pins for proper function.
When using the machine regularly please check the unit parts visually, especially screws, bolts,
welding seams and other fixtures.
Check the tightness of the unit feet.
Check if the cranks are mounted tight to the axle. Therefore you need a 14 mm socket wrench.
Important: Retighten the cranks after 10 hours of use! Damages on the cranks or axle due to a lack
of retightening are not considered a warranty case!
Check the seat post for damages due to overload.
/H-p-cosmos.local/dfs/erp$/article/cos30021ef-med600/manual/EN/20170926_cos30033ef-med600-ef-600_torqualizer_stair_instructions_for_use_EN.pdf
Abb.6: Warning indication at brake: Danger resulting from high voltage
User manual motion stair 600 med/600
Page 16 of 19