4-4-21
4-4-22
E24
Fig.4-57
VIEWFINDER
Clean the optical parts with the solut-
1A
ion(70% ether, 30% alcohol), before install-
L3
ing them.
Installing directions
of the Fresnel
L2
lens and ground glass must be carefully
Fig.4-58
observed.
Refer to Fig. 4-58.
WIND LEVER AND EXPOSURE
COUNTER
DIAL
Dial housing (C54)
4
If the wind lever turns
hard, when
Dial housing is fixed by Nut(C127), use
W38(t=0. 1, 0. 15) beneath the housing(C54).
Lever restoring spring (C58)
When
installing the restoring
spring(C58),
one
side of the spring
ends must firmly engage with the hole on the main gear(C01).
Place the spring into the position aligning
the spring end and the
hole,
and press down the spring with a screw driver. lightly.