4-6
lever,
both
lst and 2nd curtain damper
arms
must be in para-
llel with the intermediate
levers
respectively, as shown
in Fig.
4-9.
After releasing
curtains; -
Installing procedures
are:
1
Curtain
stops traveling when the damper
disk hits the stop-
per.
Then the location of the curtain edger must
be:
lst edger
5.5240.3mm inside from the frame edge
2nd edger
Overlaps the lst edger,
0.340.5 mm.
A line on the frame(B63) shows 5.5mm distant from the frame
edge.
55203
am
and
"tat
Fig.4-10
234J~05080-A
=)
Wind
up the curtains
by turn-
ing Curtain charge gear(E80)
with special tool(234J-05080-
A) as shown,until both select-
or gears are brought to a stop.
Insert the assembled
system
into the installing position.
At
which time, remove X SW(E29) if it is fixed.
3
Slide the system
to the outside to disengage
the damper
gears
from the pinion gears.
Turn the each damper
gear
counterclock-
wise, until the stud-pins
on the damper
gears
make
contact with the damper arms res-
pectively.
Pig.4-12
4
Set the damper
gears
so that
the arms
come
into the place as shown
in Fig. 4-13,
by turning the damper
gears.
If the arm
does not stop at the right
place, turn the friction disk a little by screw
driver, as to change the relative location of
the ratchet.
Pig.4-13
oF

Advertisement