4-4-10
4-4-1]
n= 16
'SHUTTER DIAL
(Fig. 4-108)
When installing Shutter dial(E125),
Dial rest (E120), Dial shaft
(E119) and Rotary SW(E128) must be put together so that the shutter
click is properly coupled with the rotary SW
contact point.
Procedures
are:
1
Coincide the rotary
contact with ''B'' terminal.
2
Coincide
''B" click hole with the click ball.
The location
of 'B"
click hole is shown in Fig. 4-37.
3
Install Dial rest to the shaft, holding the dial rest with the prot-
rusion in the front side of the camera.
Now, the protrusion engages
with the cut out section near-
est to the roary contact on the rotary plate(correct position),
4
Keep the Dial rest in the same direction when installing the Top
cover left(A08),
Install Shutter dial(E125) to the rest, coincid-
ing "B"' with the shutter speed index.
E123,
Aro.
L-1
"B" hole
Note:

Advertisement