Download Print this page

ASAHI PENTAX 6x7 Service Manual page 81

Hide thumbs Also See for PENTAX 6x7:

Advertisement

Rois
gear
mount.
2
Transfer the spring end of (C122)by tweezers
so that it engages
with the protrusion
of the gear mount.
F
Stopper
release
lever
Install Stopper release
lever(C18)
and
c18
Coupler lever(C19)in the spool shaft,
as
shown in Fig. 4-41.
c19
sg
G4
Oiling:
L-1 to the shaft and G4 to the points
:
shown.
Pig.4-41
G
ADJUSTMENT
AND OPERATION
CHECK
The following adjustment
and operation
check must be done after
the mirror
housing and body are
coupled to each other.
The
coupling
procedure
is described
elsewhere.
(1)
Spool stopper operation check
With the back cover
opened, turn the curtain charge gear (E
80)clockwise about 90°by using the special tool(234J-05080-A).
B shows
the position when the gear (E80)is wound.
C shows the
position when the gear has returned.
234J-05080-A
19
€20
(2)
lst frame stabilizer operation check
Operation of the lst frame
stabilizer
on Auto re-set
actuator
must be checked as follows:
a
When
the back cover
is opened with the shutter un-cocked,
a
proper
clearance
must
be maintained
between the step
of the
stabilizer and D-shaped
pin on the stopper
release lever,
as
shown in Fig. 4-43.
5/

Advertisement