Advertisement

Quick Links

VENUS - VENUS IN THE MBOX
VENUS HT
INSTALLATION INSTRUCTIONS AND INSTRUCTIONS FOR USE
This product is not suitable for use as a primary heater

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VENUS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for M Design VENUS

  • Page 1 VENUS - VENUS IN THE MBOX VENUS HT INSTALLATION INSTRUCTIONS AND INSTRUCTIONS FOR USE This product is not suitable for use as a primary heater...
  • Page 2: Table Of Contents

    2.4 Installation without external air supply ............2.5 Convection current ......................2.5.1 Natural convection .................... 2.5.2 Convection with a fan (optional)............. 2.5.3 Aansluiting van een M-Design (ook voor Venus in the Mbox) 2.5.4 Installation without a fan................2.6 Convection grids ....................... 3. Chimney ............................
  • Page 3 1. GENERAL (Venus - Venus in the MBox ) Transport the VENUS , Venus in the MBox upright or in difficult cases at an angle of 45°. Before starting the installation, check the proper functioning of the door Opening the window: pull the lever towards you, the window will open with the movement. If the applian- ce is already hot, use the poker provided.
  • Page 4 Note: Only light a fire when there is a light wind of 5 km per hour or more. Do not make a fire when there is no wind or when there is fog. It goes without saying that you should also not light a fire when the heating notice is in effect. Likewise, poorly constructed or unmaintained chimneys prevent the fire from obtaining oxygen or, worse, blowing smoke back into the house.
  • Page 5: Installation

    - ask your supplier for advice. VENUS has been designed so that it is easy to install. The combustion chamber can be completely slid out of the encasement. This makes it easy for one single person to easily install the appliance and a second person is only necessary to help a few minutes to slide the combustion chamber back in.
  • Page 6: Positionng The Firecplace On The Floor

    The device must be installed so that the front of it remained free space on a minimum ground plan of about 1 x 1 m. If you use fireplace Venus with feet, place the appliance on a stable surface using the adjustable feet. Adjust the height of the appliance turning the bolt.
  • Page 7: Installation Without External Air Supply

    It is also compulsory to connect flexible pipes for convection. Opening for the external air supply is located according ordered VENUS type, Opening can be at the bottom front part or VENUS BOX with wall console has opening at bottom back side.
  • Page 8: Convection Current

    It is compulsory to open at least 2 hot air vents at the top of the appliance. The VENUS has been constructed in such a way that if it is connected without a fan, but with hot air vents, the air at the front, under and on the sides of the appliance is drawn in.
  • Page 9 2.5.3 Connecting the M-Design drive (also for the Venus in the Mbox) Use a flathead screwdriver to open the You will find 2 lever clamps housing WAGO surface-mounted drive You can choose to cut out the passage for the cables (above or behind the case)
  • Page 10: Installation Without A Fan

    2.5.4 Installation without fan Installation without fan: Convection ducting must be installed. When the VENUS is installed there is possibility to choose distribution of hot air with ducts. Without a fan, the flexibles for convection air MUST be ON. You can use 2 grilles or, in case of lack of space, 1 grille ( see illustration below ).
  • Page 11 2.6 Grids Designrooster (outlet) with 2 connections Designgrid ( outlet ) of/ou Designrooster (oultet) with 4 connections 4 dm² 2 dm² Inlet Grid Inlet Grid...
  • Page 12: Chimney

    •The existing obstacles in the vicinity of the opening into the flue must be taken into account. •Do not connect more than one stove to a chimney. Standaarddiameter flue opening Venus V23 The VENUS stoves have a standard flue opening of 150mm or Ø 180 mm. in diameter according drawings in chapter 8. Certain Venus 530 Ø150...
  • Page 13: Removing The Flue Damper

    Instructions for installation and use VENUS V23 ND REMOVING OF DEFLECTOR V - 7 - 3 parts of deflector in the cut view At the same time lift the rear...
  • Page 14: Minimum Distances To Be Respected During Installation

    4. Minimum distances to be respected during installation Minimum distance Distance to flammable materials (glass side) 1000 Distance from door to ceiling 1100 Distance to flammable materials at side of door Distance from convection grate to flammable ceiling 250 Distance to flammable materials in cabinet Distance from door to flammable floor...
  • Page 15: Technical Datas - Specifications

    5. Technical Data - Specifications...
  • Page 16: General Recommendations

    6.1 Maintenance • In addition to regularly keeping the window clean, you must have your chimney swept at least once a year for the VENUS to function properly. (Not only is this legal, but it is also for your safety.) •...
  • Page 17 8. Drawings Venus 530 V23 int. VENUS 530 V23 Venus 630 V23 int. VENUS 630 V23...
  • Page 18 Venus 730 V23 int. VENUS 730 V23...
  • Page 19 Venus 700 V23 int. VENUS 700 V23 Venus 850 V23 int. VENUS 850 V23...
  • Page 20 Venus 1000 V23 1109 1049 1090 1021 int. VENUS 1000 V23 Venus 850D V23 int. VENUS 850D V23...
  • Page 21 Venus 530DC V23 177,5 348,5 int. VENUS 530DC model 2023 Venus 630DC V23 177,5 348,5 int. VENUS 630DC model 2023...
  • Page 22 Venus 850DC V23 177,5 348,5 int. VENUS 850DC model 2023 Venus 530CL V23 int. VENUS 530 CL V23...
  • Page 23 Venus 630CL V23 int. VENUS 630 CL V23 Venus 850CL V23 int. VENUS 850 CL V23...
  • Page 24: Spare Parts

    9. Spare parts...
  • Page 27: Venus In The Mbox

    VENUS IN THE MBOX INSTALLATION INSTRUCTIONS AND INSTRUCTIONS FOR USE This product is not suitable for use as a primary heater...
  • Page 28 SUMMARY VENUS IN THE MBOX 1. Installation ..........................2.1 Installation operations ....................2.2 Stand-alone installation with Woodbox............2.3 Suspended installation against a wall with foot........31-32 2.4 Fan (option) .......................... 2.4.1 Installation of the fan ..................2.5 Combustion air supply ....................
  • Page 29: Installation

    - Screw on the smoke extractor while fitting the flue pipe. Installation if you wish to mount the Venus in the MBox entirely on the wall bracket (caution: the appliance is very heavy) - Install the foot on the floor against the wall - Fix the wall bracket to the wall (use M8x100 anchor bolts).
  • Page 30: Stand-Alone Installation With Woodbox

    2.2 Venus in the MBox: Stand-alone installation with Woodbox The Venus in the MBox is delivered on a pallet. Unscrew the wood screws (A). Tilt the fireplace back and unscrew the 4 bolts (B) to remove the support profile. Keep the 4 pan-head screws handy for securing the wood box at a later date.
  • Page 31 2.3 Venus in the MBox: Installation against a wall. (take into account the ‘Full wall’ guideline) We recommand to remove the combustion chamber out of the Mbox. Open the door unscrew the bolt and nut to remove the chimney hood Remove chamot stones Slide the combustion chamber out of the MBox.
  • Page 32 Position the foot against the wall. Present the Mbox and wall bracket against the wall and mark where the holes should be drilled. Hang the Venus M Box on the wall bracket Replace the combustion chamber in the MBox. Replace the chimney hood and install the chamot...
  • Page 33: Fan (Option)

    2.4 Fan (option) (installation Dimmer : page 8) Important: if you have chosen to use a fan, you must first fit it as described below. The fan box includes Fan protection wire 220V Cable Fan 2x M5x6 / 2x M5x10...
  • Page 34: Installation Of The Fan

    M-Design dimmer (to be ordered separately) fan cable connection IMPORTANT : if fresh air is connected from outside and the Venus is installed hanging, a fan cannot be taken as an option If you still want to use a fan and connect fresh air from outside, you can install the M-Box with a base...
  • Page 35: Combustion Air Supply

    Combustion air supply control 2.6 Connection without air supply from outside However, if it is not possible to obtain fresh air from outside, Venus in the MBox can be installed. Venus in the MBox draws combustion air from the living room.
  • Page 36: Chimney

    B-B ( 1:7 ) B-B ( 1:7 ) A-A ( 1:7 ) A-A ( 1:7 ) to inlet VENUS connection fresh air Ø100mm possibility of fresh air intake on the underside via an open plinth If the fresh air is provided at the bottom, the inlet plate at the rear must be replaced by a supplied flat plate 2.7.
  • Page 37 OPTION console for wall 306,5 306,5 VENUS 530 V23 in the box + console for wall Venus 530 in the MBox + Woodbox extern air inlet 306,5 306,5 VENUS 530 V23 in the box + wood box...
  • Page 38 OPTION console for wall 356,5 356,5 VENUS 630 V23 in the box + console for wall Venus 630 in the MBox + Woodbox extern air inlet 356,5 356,5 VENUS 630 V23 in the box + wood box...
  • Page 39 OPTION console for wall 406,5 406,5 VENUS 730 V23 in the box + console for wall Venus 730 in the MBox + Woodbox extern air inlet 406,5 406,5 VENUS 730 V23 in the box + wood box...
  • Page 40 OPTION console for wall 391,5 391,5 VENUS 700 V23 in the box + console for wall Venus 700 in the MBox + Woodbox extern air inlet 391,5 391,5 VENUS 700 V23 in the box + wood box...
  • Page 41 OPTION console for wall 466,5 466,5 VENUS 850 V23 in the box + console for wall Venus 850 in the MBox + Woodbox extern air inlet 466,5 466,5 VENUS 850 V23 in the box + wood box...
  • Page 42 1000 1083 int. OPTION console for wall VENUS 1000 V23 in the box + console for wall Venus 1000 in the MBox + Woodbox 1000 1033 1083 extern air inlet 541,5 541,5 VENUS 1000 V23 in the box + wood box...
  • Page 43 Venus 850D in the MBox extern air inlet VENUS 850D V23 in the box Venus 850D in the MBox + Woodbox 466,5 466,5 VENUS 850D V23 in the box + wood box...
  • Page 44 Venus 530CL in the MBox extern air inlet int. OPTION console for wall VENUS 530 CL V23 in the box + console for wall Venus 530CL in the MBox + Woodbox extern air inlet VENUS 530 CL V23 in the box + wood box...
  • Page 45 Venus 630CL in the MBox extern air inlet int. OPTION console for wall VENUS 630 CL V23 in the box + console for wall Venus 630CL in the MBox + Woodbox extern air inlet VENUS 630 CL V23 in the box + wood box...
  • Page 46 Venus 850CL in the MBox extern air inlet int. OPTION console for wall VENUS 850 CL V23 in the box + console for wall Venus 850CL in the MBox + Woodbox extern air inlet VENUS 850 CL V23 in the box + wood box...
  • Page 47 VENUS HT INSTALLATION INSTRUCTIONS AND INSTRUCTIONS FOR USE This product is not suitable for use as a primary heater...
  • Page 48 SUMMARY VENUS HT 1. General ............................1.1 Transport and Installation ..................2. Installation ..........................2.1 Installation operations ....................2.2 reception of the fireplace ..................2.2.1 Combustion chamber ..................2.3 Chimney ........................... 2.4 Dimensions of the decorative tube ..............50-53 2.5 Ceiling piece .........................
  • Page 49 1. General 1.1 Transport and installation • Transport the Venus HT upright or in difficult cases at an angle of 45°. OPENING AND CLOSING THE DOOR: PROCEED SLOWLY WHEN OPENING THE DOOR WHEN THE FIRE IS ON. Ope- ning the door too quickly causes smoke deposits in the room.
  • Page 50 MINIMUM HEIGHT OF THE CHIMNEY IN TERMS OF ITS REDUCTION Ø Ø Ø Venus 700 ≥ 4m (O) ≥ 5m (S) Venus 850 ≥ 4m (O) ≥ 5m (S) Venus 1000 ≥ 5m (O) ≥ 6m (S) Venus 850D ≥ 4m (O) ≥...
  • Page 51 VENUS 850HT WITH SHORT FRAME 360° STANDARD 1550mm WITH LONG FRAME 360°...
  • Page 52 VENUS 850 DHT WITH SHORT FRAME 360° STANDARD 1550mm WITH LONG FRAME 360°...
  • Page 53 VENUS 1000HT WITH SHORT FRAME 360° STANDARD 1500mm WITH LONG FRAME 360°...
  • Page 54 2.5 Ceiling piece 850HT/DHT 700HT 1000HT 2.6 CONNECTION We recommend a solid stainless steel pipe for the connection. The device is supplied without this tube. As a result, you will have to provide a tube yourself. 2.6.1 Ceil Cing connection A minimum distance of 5 cm must be maintained between the ceiling connection and the decorative pipe.
  • Page 55 2.7 Flue damper adjustment (page 11) 2.8 Removing the flue damper (page 12) 3. Minimum distances to be respected during installation (page 13) 4. Technical datas - specifications (page 14) 5. General recommendations and maintance (page 15) 6. Warranty (page 15)
  • Page 56 7. Drawings 1050 int. VENUS V23 700 HT 1190 int. VENUS V23 850 HT...
  • Page 57 1190 int. VENUS V23 850D HT 1350 1111 int. VENUS V23 1000 HT...

This manual is also suitable for:

Venus in the mboxVenus ht

Table of Contents