MONT73 Series Elevator Intergrated Controller Starting Guide V1.0 2020.03...
Page 2
Shenzhen Hpmont Technology Co., Ltd. MONT73 Series Starting Guide V1.0 MONT73 Open-loop Integrated Controller Starting Guide Thank you for using Hpmont MONT73 open-loop integrated controller. Version and Revision Records Time: 2020/3 Version: V1.0 Chapter Content V1.0 published •...
Support mobile phone bluetooth debugging • Maximum 16 floors with expansion board IOB • Multiple security protection, accord with GB7588-2003 4 high voltage inputs, 25 digital inputs, 25 relay outputs, 24 button input and • output interfaces MONT73 Series Starting Guide V1.0...
RUN button of keypadperforms the door opening action; Keypad open and STOP button performs the door closing action. closedoor operation MONT73 Series Starting Guide V1.0...
Page 8
Users can use this function to find the parameters that are User verification menu inconsistent with the factory settings. MONT73 Series Starting Guide V1.0...
Only standard MONT73 models are listed here. For other power grade products’detailed parameters are not listed here because they are less used on site. If you need this kind of products, please contact us directly. MONT73 Series Starting Guide V1.0...
The recommendedbreakerMCCB, the contactor capacity and the recommended cross-sectional area of the copper core insulated wire are shown in the table below. MONT73 Input Power Terminal Wiring Power Terminal Wiring Lug MT73-4T3P7 1.2-1.5 MT73-4T5P5 1.2-1.5 MT73-4T7P5 2.5-3.0 MT73-4T011 2.5-3.0 MT73-4T015 2.5-3.0 MONT73 Series Starting Guide V1.0...
Overvoltage protection. 2. Please install the braking resistor in a well-ventilated metal cover. The temperature of the braking resistor is very high during operation. Do not touch it directly. MONT73 Series Starting Guide V1.0...
1. Information Shenzhen Hpmont Technology Co., Ltd. 1.4 System Configuration Figure 1–1 MONT73 system configuration MONT73 Series Starting Guide V1.0...
Page 14
MT70-CIC-B For elevator module MT70-CIC-E-LY Control MT70-IOB-A cabinet Each Optional Car top Expansion For floor MT70-IOB-B or mani- Elevator Choose one of Card expansion pulator configure one the three Manipul MT70-IOB-C ator MONT73 Series Starting Guide V1.0...
Modbus communication terminal, connects external RJ45 interface keypad to view and modify the parameters of the main control board Note: If the relay is connected to an AC 220V voltage signal, the current limit must be within 3A. -12- MONT73 Series Starting Guide V1.0...
When 2, 3Pin is shorted, the high electrical level is valid (factory setting). • 1.6.4 Modbus Communication Terminal Definition RJ45 MOD+ 4 - 6 MOD- Unused connectingexternal keypad can view and modify the parameters of the main control board MONT73 Series Starting Guide V1.0 -13-...
The keypad displays the information of the MCB board and simple command input. The function parameters are F0 - F11, as shown in the following table. Function Floor and running direction information Call command input Fault reset Run times display Test function UCMP start test -14- MONT73 Series Starting Guide V1.0...
Page 20
F8 and in the test function mode, the SET key is equivalent to the door close key. Group F11: After entering the group F11, change the parameter from "0" to "1" to enable the UCMP test function. UCMP start test MONT73 Series Starting Guide V1.0 -15-...
F29.01 - F29.20 F29.01 - F29.20 • • • interface setting setting setting Car call MOD2+/MOD2- Hall call MOD+/MOD- MOD+/MOD- MOD+/MOD- communication Installation Elevator control panel Car top or control box Control box position MONT73 Series Starting Guide V1.0 -17-...
Collecting floor instructions and floor information display as communication in the • car, only communicate with the main control board through 4 wires. Reduce the number of accompanying cables. Ø3.5 MT70-IOB-A Indicators POWERSCI Jumper +24V +24V MOD+ MOD- COM Figure 1-5 MT70-IOB-A -18- MONT73 Series Starting Guide V1.0...
Page 24
MCB board Jumper Description Jumper Description Modbus communication matching resistor selection: When 1, 2Pin is shorted, the matching resistance is effective. • When 2, 3Pin is shorted, the matching resistance is invalid (factory setting). • MONT73 Series Starting Guide V1.0 -19-...
Small size, can be directly installed in the control box, greatly reducing the number • of cables required for traditional parallel systems. X1-X3 Indicators Y1-Y5 Indicators MT70-IOB-B L1-L20 Indicators MOD2+ MOD2- +24V MOD+ MOD- COM 4-Ø4.5 Figure 1-6 MT70-IOB-B -20- MONT73 Series Starting Guide V1.0...
Page 26
Effective on, inactive off (green light) indicator Blinks when normal, turns off when abnormal Power Indicator (green light) The communication with the main control board Communication indicator blinks normally, and the communication goes off abnormally (green light) MONT73 Series Starting Guide V1.0 -21-...
Small size, can be directly installed in the control box, greatly reducing the number of cables required for traditional parallel systems. X1-X3 13.9 Indicators Y1-Y5 21.2 39.1 Indicators L1-L20 Indicators 25.4 40.4 MT70-IOB-C 6-14.1 +24V MOD+ MOD- COM Figure 1-7 MT70-IOB-C -22- MONT73 Series Starting Guide V1.0...
Page 28
Modbus Requires IOB extension: F28.00 Bit2 = 1 • Note: When the relay terminal is connected to AC 220V, Y1 - Y4 must be limited to 3A and Y5 must be limited to 5A. MONT73 Series Starting Guide V1.0 -23-...
Page 29
When 2, 3Pin is shorted, the high level is valid (factory setting). • SCI communication matching resistor selection: When 1, 2Pin is shorted, do not use matching resistors; • When 2, 3Pin is shorted, use matching resistor (factory setting). • -24- MONT73 Series Starting Guide V1.0...
264: 14F front door 364: 14F rear door F13.23 SK7-L23 0 [0 - 366] 265: 15F front door 365: 15F rear door 266: 16F front door 366: 16F rear door F13.24 SK7-L24 0 [0 - 366] MONT73 Series Starting Guide V1.0 -25-...
Page 31
Bit2: IOB extension function 0: Prohibited 1: Enable Bit3: Unused F28.00 enhancement 0 [0 - 65535] parameters Bit4: IOB-B X1 terminal function 0: No 1: Open the front door and close the door in place -26- MONT73 Series Starting Guide V1.0...
Page 32
Bit12 & Bit11: IOB-B communication abnormal and cancel floor command 00: Not cancel floor commands 01: Cancel car call command 10: Cancel hall call command 11: Cancel car call and hall call command Bit13 - Bit15: Unused MONT73 Series Starting Guide V1.0 -27-...
Page 33
0 [0 - 55] 20: Fire back to base station output 21: Buzzer output 22: Overload output 23: Arrival clock output F28.10 IOB-Y10 0 [0 - 55] 24: Full load output (LWX) 25: Inspection output -28- MONT73 Series Starting Guide V1.0...
Page 34
0 [0 - 65535] 0: No output • 1: Output Y1 - Y20 • status Bit0 corresponds to Y17, Bit3 corresponds to Y20 F28.22 0 [0 - 15] 0: No output • 1: Output • MONT73 Series Starting Guide V1.0 -29-...
Page 35
0 [000 - 366] 244: 14F front door 344: 14F back door 245: 15F front door 345: 15F back door F29.14 SK7-L14 0 [000 - 366] 246: 16F front door 346: 16F back door -30- MONT73 Series Starting Guide V1.0...
Page 36
365: 15F back door down 266: 16F front door down 366: 16F back door down F29.30 SK7-L30 0 [000 - 366] Note: The F29 (IOB) and F13 (MCB) are mutually exclusive. Cannot be set repeatedly. MONT73 Series Starting Guide V1.0 -31-...
1. Information Shenzhen Hpmont Technology Co., Ltd. 1.8 LCD Keypad (MT70-LCD-D) MONT73 series have optional LCD keypad (MT70-LCD-A). Digital Operator STOP Function Enter or exit programming key Enter lower menu or confirm to save the data At keypad control (F00.07 = 0), to start MONT73;...
Shown as Figure 1-11. 【E0038 】 【E0038 】 Upper force decelerate te switch disconnection Press to Cause Press PRG quit Press to Resource Press STOP reset Figure 1-11 Display interface at fault MONT73 Series Starting Guide V1.0 -33-...
Page 39
There is no difference between the door lock connection of front • door and back door Over-load / full- If elevator is over-load, display “over load”; If full-load, display “full load” load state 1213 -34- MONT73 Series Starting Guide V1.0...
Enter to Save present value and Enter to function Enter to setting function group return to function para. para. setting level parameter level setting level setting level MONT73 Series Starting Guide V1.0 -35-...
• Wiring checking of communication line and power line. Railway communication line is twisted pair and the twisting distance is less than • 35mm. Please separate the communicaiton line and power supply line. • MONT73 Series Starting Guide V1.0 -37-...
MCB board through the D group. Gene ral Asyn. Motor Main Control Board Specific ation Parame ter I/O and L Terminals F00.00 - F00.07 F07.00 - F07.05 Group F12 / F13 Group F03 / 04 Figure 2-1 Function settings -38- MONT73 Series Starting Guide V1.0...
Page 44
Urgently Dec at the ending 0.20 [0.02 -2.00m/s F03.05 section F03.06 Inspection running Acc 0.25 [0.02 -2.00m/s F03.07 Inspection running Dec 1.00 [0.02 -2.00m/s F03.08 Emergency running Acc 0.25 [0.02 - 2.00m/s MONT73 Series Starting Guide V1.0 -39-...
Page 45
Rated current (A) [0.0 - 999.9] but cannot exceed the F07.03 Rated frequency (Hz) 50 [1.00 - F00.05] capacity of controller F07.04 Rated speed (rpm) 1440 [1 - 24000] F07.05 Power factor 0.85 [0.001 - 1.000] -40- MONT73 Series Starting Guide V1.0...
Page 46
116 [0 - 55] 29: Direct signal constant (NSB) 30: Commutation signal constant (ACB) 31: Independent signal constant (ISS) F12.11 SK1-X11 117 [0 - 55] 32: Front and back door toggle switch constant (GABS) MONT73 Series Starting Guide V1.0 -41-...
Page 47
1: High voltage safe F12.26 SK4-X26 2 [0 - 99] circuit (JT) 4: High voltage door lock short circuit signal 2: High voltage door F12.27 SK4-X27 3 [0 - 99] lock 1 (DS1) 5 - 99: Unused -42- MONT73 Series Starting Guide V1.0...
Page 48
F12.43 SK9-Y15 0 [0 - 55] 35: Ladder lock constant closed output 36: High 7 short code a display output F12.44 SK9-Y16 25 [0 - 55] 37: High 7 short code b display output MONT73 Series Starting Guide V1.0 -43-...
Page 49
22 [0 - 55] 52: Binary code or gray code output D 53: Fault output indication 54: Elevator running output F12.51 SK7-Y23 0 [0 - 55] 55: Input phase loss or power off relay output -44- MONT73 Series Starting Guide V1.0...
Page 50
244: 14F front door 344: 14F back door F13.13 SK7-L13 221 [0 - 366] 245: 15F front door 345: 15F back door 246: 16F front door 346: 16F back door F13.14 SK7-L14 222 [0 - 366] MONT73 Series Starting Guide V1.0 -45-...
Page 51
366: 16F back door down Output F13.27 0 [0 - 65535] Bit0 corresponds to L0, Bit15 corresponds to L16 logic F13.28 0 [0 - 255] Bit0 corresponds to L17, Bit7 corresponds to L24 setting -46- MONT73 Series Starting Guide V1.0...
During the rotation auto-tuning, if the vibration of the motor or even an overcurrent occurs, press the STOP key to terminate the auto-tuning. Countermeasure: Appropriate adjustment of F07.21 (suppression of vibration mode) and F07.22 (suppression of vibration coefficient) can eliminate the vibration of the motor. MONT73 Series Starting Guide V1.0 -47-...
Note: During the inspection operation, pay attention to whether E76, E77, E79 faults occur. If there is a fault, it indicates that the railway switch is abnormal. Please check whether the Dec switch and the leveling switch are reversed or missing. -48- MONT73 Series Starting Guide V1.0...
Page 54
If so, stop in time. At inpsection runtime, if the shaft switch is not installed in place, the system may alarm fault, which can be shielded by function parameter F26.12 (inspection parameter setting). MONT73 Series Starting Guide V1.0 -49-...
Decel distance 1m Up Dec point Floor height 3m Down Dec point Decel distance 1m Leveling position 1 Leveling plate Note: Up and down-Dec signal have to be set in group F12 X terminals. -50- MONT73 Series Starting Guide V1.0...
You can monitor door open & close arrival, light curtain, safety edge and other signals via checking keypad D04.00 & D04.01. Under inspection mode, light curtain and safty edge siganl acted, the door will not open, but can monitor signal whether it is OK. MONT73 Series Starting Guide V1.0 -51-...
After the door lock circuit on, the fault can be automatically reset. Contactor Adhesion Protection Check whether system could protect when manually adhere running contactor, brake contactor, and door-closed contactor, make sure system could protect. -52- MONT73 Series Starting Guide V1.0...
Page 58
E0038 (up forced Dec switch off). Note: When forcelly changing speed acted, the elevator will crawl at F04.02 (creep speed) to leveling, when the leveling signal is valid, by adjusting F03.13 (parking Dec) to ensure the leveling precision. MONT73 Series Starting Guide V1.0 -53-...
MCB board X1 - X24 (F12.01 - F12.24 setting). Switch fire button, whether the lift returns to the fire station, door open after reaching leveling. Advanced detail parameters refer to F26.16 of Bit3, Bit6. • -54- MONT73 Series Starting Guide V1.0...
Page 60
The elevator stops due to error or other reasons. In order to meet the running conditions, the lift will be running at F11.03 (re-leveling speed) to leveling zone. When reaching leveling area (one switch acted, the other not acted), the elevator will decel at F11.04 (speed) to stop. MONT73 Series Starting Guide V1.0 -55-...
Increase F08.05, or decrease F08.04 frequency is too close Speed loop PI Decrease PI-parameter F08.02, F08.03 Cons- parameters too high tant Vibration Current loop PI speed speed Decrease PI-parameter F09.00, F09.01 is too high -56- MONT73 Series Starting Guide V1.0...
Page 62
Cabin slipping solution Slip compensation Increase the slip compensation gain F07.17, Leveling inadequate F07.19 slip compensation value accuracy related with Torque output is Increase low speed loop PI parameters the load insufficient F08.00, F08.01 MONT73 Series Starting Guide V1.0 -57-...
Acc / Dec (F03.00 / F03.03): Ratio change of velocity. • Rapid Acc / rapid Dec (F03.01, F03.02 / F03.04, F03.05): The rate of change of Acc / Dec. • S curve decel switch settings related with the actual installation switch location. -58- MONT73 Series Starting Guide V1.0...
1: Check if the steel cord has excessive oil exudation, erase with a cloth. 2: The rope wrap angle is reasonable traction sheave. 3: Whether lift balance coefficient is correct, if incorrect, do balance checking, range 0.4 - 0.5. MONT73 Series Starting Guide V1.0 -59-...
If it is under leveling, need to increase the corresponding parameter value. The Fatigue Test of New Lift After the new lift installed, you need to do the trial testing. Can set random operation or specified operating mode by parameters F25. -60- MONT73 Series Starting Guide V1.0...
Under inspection mode, the MCB board keypad set F02 = 1, press the SET key to • reset the fault. Note: When setting F16.05 Bit10 = 1, E65 fault may be reset by cutting off power. Not recommended for this method. MONT73 Series Starting Guide V1.0 -61-...
1 opens controlled X input signal requires • This signal can be connected • manually) door 2 signal, to cabin switch or button, it is otherwise, only open controllered by cabin people door 1 -62- MONT73 Series Starting Guide V1.0...
Page 68
Description Dual Hall Call (2 Cases) • If there is only one door, the same meaning for dual calls. Simply wiring in parallel can be achieved. If there are two doors, see usage through door description. • MONT73 Series Starting Guide V1.0 -63-...
0: Normal display Manual door, door 1: Manual door display F26.28 Bit6 lock circuit off Car door circuit off, it is • reminding displayed as "C" and "floor number", if the landing -64- MONT73 Series Starting Guide V1.0...
Page 70
Case 2: Using one high voltage lock signal R-cam operation mode High-voltage lock signal There is call command, the car door lock is Car door lock signal F12.26 X26 = 2 on, R-cam output all the time, lift start MONT73 Series Starting Guide V1.0 -65-...
110%, it will be overload signal. Note: 1. Select the input terminal full load & overload signal, overload, full load will be acted after setting. 2. The switch can be used together with the analog signal. -66- MONT73 Series Starting Guide V1.0...
Some faults may auto-reset. • Fault Code Description The keypad displays five data: E + Fault code The MCB’s small keypad displays three data: E + Fault code The keypad can prompt fault code causes and countermeasures. MONT73 Series Starting Guide V1.0 -67-...
302: Hardware constant 2: Main circuit output is short speed over current wiring 303: Motor overcurrent 3: The motor has not done software constant speed parameter auto-tuning overcurrent 4: Load is too heavy -68- MONT73 Series Starting Guide V1.0...
Page 74
3: Check whether the fan and the 801: FO fault protection 2: Motor wiring is too long ventilation duct are normal (level trigger) 3: Work environment is 4: Please contact the supplier for overheating repairing 4: Power module is damaged MONT73 Series Starting Guide V1.0 -69-...
Page 75
1207: No-load current self- tuning is too small 1208: Static auto-tuning, the upper and lower limit switches are valid at the same time Fault reasons: 1: Parameter auto-tuning timeout 2: Over current at parameter auto-tuning -70- MONT73 Series Starting Guide V1.0...
Page 76
3: Controller output torque is parameter (F08) not enough 1804: Speed deviation 5: Check the motor parameter 4: Speed-loop PI parameter level 4 6: Restart parameter auto-tuning setting is improper 5: Motor parameter error 6: F10.12 error MONT73 Series Starting Guide V1.0 -71-...
Page 77
E0022 (E22): Keypad EEPROM read / write Level 1 Countmeasure faulty Fault reasons: 1: Replace the keypad Keypad EEPROM circuit failure 2: Contact the supplier for repairing 3: Keypad manually reset to continue normal use (exclude parameter upload and download) -72- MONT73 Series Starting Guide V1.0...
Page 78
1: Controller output torque is 2: Correctly set speed-loop PI not enough parameter (group F08) 2: Speed-loop PI parameter 3: Restart parameter auto-tuning setting is improper 4: Check motor parameter 3: Motor parameter error MONT73 Series Starting Guide V1.0 -73-...
Page 79
4100: Safety circuit Safety circuit signal disconnection disconnection 2: Check the safety circuit power supply circuit 3: Check the safety circuit contactor signal 4: Check the safety circuit feedback contact signal characteristics (NO or -74- MONT73 Series Starting Guide V1.0...
Page 80
Up / down forced Dec Dec switch disconnection switches simultaneously 2: up / down forced Dec signal disconnected characteristics (normally open or normally closed) 3: F26.12 (inspection parameter setting) of Bit4 is set as 1 MONT73 Series Starting Guide V1.0 -75-...
Page 81
1: Check the communication cable 5200: Calling Hall call communication did 2: Check the 24V power supply communication failure not receive the correct data 3: Check whether the HCB address conflicts 4: Check D06.01 communication degree of interference -76- MONT73 Series Starting Guide V1.0...
Page 82
MCB corresponding feedback input point acts 4: Check whether the output characteristics of contactor is consistent with that of MCB 5: Check the contactor coil circuit 6: F26.17 = 1, the fault will restore MONT73 Series Starting Guide V1.0 -77-...
Page 83
5805: Lower level signal disconnected adhesion 3: Check the MCB input point 5803: Upper level signal 5806: Lower leveling signal is adhesion disconnected Fault reasons: Leveling / door zone signal is adhesion or cut off -78- MONT73 Series Starting Guide V1.0...
Page 84
1: Speed is larger than 2: Check the advanced open block door is too fast / No advanced open speed + (MT70-AOB-A) leveling signal 0.050m/s 2: Advanced open operation is not in the leveling MONT73 Series Starting Guide V1.0 -79-...
Page 85
Faulty subcode: Fault reasons: 1: Check whether the integrated computer and motor lines are 7500: The currenti s too Running current is too small disconnected small 2: See if F27.13 / F27.14 is appropriate -80- MONT73 Series Starting Guide V1.0...
E0048, E0049, E0055 Can be reset by inspection button E0073 Forbidden fast car alarm Can be reset automatically MONT73 Series Starting Guide V1.0 -81-...