DSX-1-to-V.35/V.11 Configuration

To connect a DSX-1-compatible unit on the CO side and a V.35/V.11-compatible
unit on the CP side, configure the units as follows. Terminal Mode factory defaults
are in bold (for Switchpack mode defaults, see Appendix C,
Definitions

V.35/V.11-to-V.35/V.11 Configuration

To connect two V.35/V.11-compatible units, configure the units as follows.
Terminal Mode factory defaults are in bold (for Switchpack mode defaults, see
Appendix C,
7914-A2-GB20-00
).
Configuration
V.35/V.11-Compatible Unit
Option
(Customer Premises)
Card Type
CP
Payload Rate
U (Unframed 1544 kbps)
1 – 24 (64 – 1536 kbps)
Framing
N/A
T1 Line Encode
N/A
Line Build-Out
N/A
Switchpack Definitions
Configuration
V.35/V.11-Compatible Unit
Option
(Customer Premises)
Card Type
CP
Payload Rate
U (Unframed 1544 kbps)
1 – 24 (64 – 1536 kbps)
Timing
Loop (not configurable)
February 1998
Switchpack
DSX-1-Compatible Unit
(Central Site)
CO
See Table C-1 in Appendix C.
Use D4, Extended Superframe, or
Unframed.
B8ZS or AMI
Enter 4 at the Config command
prompt. Select from the following
options:
1) 0 to 133 ft
2) 133 to 266 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 655 ft
).
V.35/V.11-Compatible Unit
(Central Site)
CO
Must be same as CP side
Internal or External
Worksheets
A-3