DSX-1-to-DSX-1 Configuration

A-2
Multiplexer
T1
DSX-1 Unit
Customer Premises
To connect two DSX-1-compatible units, configure the units as follows. Terminal
Mode factory defaults are in bold (for Switchpack mode defaults, see
Appendix C,
Switchpack Definitions
Configuration
DSX-1-Compatible Unit
Option
(Customer Premises)
Card Type
CP (default)
T1 Line Encoding
B8ZS or AMI
Framing
D4, Extended Superframe,
or Unframed
Line Build-Out
Enter 4 at the Config
command prompt. Select
from the following options:
1) 0 to 133 ft
2) 133 to 266 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 655 ft
February 1998
Cross-campus
2-wire facility
DSX-1 Unit
).
DSX-1-Compatible Unit
(Central Site)
CO
Must be same as CP side
Must be same as CP side
Enter 4 at the Config command
prompt. Select from the following
options:
1) 0 to 133 ft
2) 133 to 266 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 655 ft
Multiplexer
T1
Central Site
97-15718
7914-A2-GB20-00