Technical specifications
9.6 Sensor evaluation of the fail-safe channels
● 1oo2 evaluation
The slot 2 was set with "1oo2 (2v2)-evaluation, EMERGENCY STOP". The
EMERGENCY STOP button is evaluated.
Bit 0 determines whether or not the EMERGENCY STOP button was pressed. The bit
can take on the following values:
– 0 = EMERGENCY STOP button pressed or error
– 1 = EMERGENCY STOP button not pressed
94