Paradyne COMSPHERE 3810 Quick Reference Manual page 7

Comsphere 3800 series
Hide thumbs Also See for COMSPHERE 3810:
Table of Contents

Advertisement

Model 3820 Network Connection
Use the following procedures to connect a Model 3820 to the dial or 2-wire leased-line
network interface:
1. Insert the 6-position, 4-conductor modular plug into the jack labeled DIAL / LEASED
(3820).
2. Insert the other end of the modular cord into the network interface.
0
1
PWR
6-POSITION,
4-CONDUCTOR PLUG
FOR TELEPHONE SET
6-POSITION, 4-CONDUCTOR
PLUG FOR PERMISSIVE
DIAL NETWORK OPERATION
(CONNECTS WITH
RJ11C TYPE JACK)
2-WIRE LEASED-LINE
NETWORK OPERATION
(CONNECTS WITH
6-POSITION CENTER PAIR
LEASED JACK)
PHONE
DIAL
LEASED
LEASED
(3810)
(3820)
– OR –
5
NMS
DTE
HUBBING
DEVICE
98-16196

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3811Comsphere 3820

Table of Contents