Omnitron Systems RuggedNet 10GMGPoEBT/Si User Manual

Omnitron Systems RuggedNet 10GMGPoEBT/Si User Manual

Unmanaged multi-gigabit/multi-rate 60/100w poe 10gigabit ethernet switch

Advertisement

Quick Links

RuggedNet
10GMGPoEBT/Si
®
Unmanaged Multi-Gigabit/Multi-Rate
60/100W PoE 10Gigabit Ethernet Switch
User Manual
38 Tesla, Irvine, CA 92618 USA
Phone: (949) 250-6510; Fax: (949) 250-6514
General and Copyright Notice
This publication is protected by U.S. and international copyright laws. All rights
reserved. The whole or any part of this publication may not be reproduced, stored
in a retrieval system, translated, transcribed, or transmitted, in any form, or by
any means, manual, electric, electronic, electromagnetic, mechanical, chemical,
optical or otherwise, without prior explicit written permission of Omnitron Systems
Technology, Inc.
The following trademarks are owned by Omnitron Systems Technology, Inc.:
FlexPoint
, FlexSwitch
, iConverter
TM
TM
OmniConverter
, RuggedNet
, Omnitron Systems Technology, Inc.
®
®
the Omnitron logo.
All other company or product names may be trademarks of their respective owners.
The information contained in this publication is subject to change without notice.
Omnitron Systems Technology, Inc. is not responsible for any inadvertent errors.
Warranty
This product is warranted to the original purchaser (Buyer) against defects in
material and workmanship for a period of two (2) years from the date of shipment.
A five (5) year warranty may be obtained by the original purchaser by registering
this product at www.omnitron-systems.com/support within ninety (90) days from the
date of shipment. During the warranty period, Omnitron will, at its option, repair or
replace a product which is proven to be defective with the same product or with a
product with at least the same functionality.
For warranty service, the product must be sent to an Omnitron designated facility,
at Buyer's expense. Omnitron will pay the shipping charge to return the product
to Buyer's designated US address using Omnitron's standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to product malfunctions resulting from
improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-
supplied equipment, Buyer-supplied interfacing, unauthorized modifications or
tampering with equipment (including removal of equipment cover by personnel not
specifically authorized and certified by Omnitron), or misuse, or operating outside
the environmental specification of the product (including but not limited to voltage,
ambient temperature, radiation, unusual dust, etc.), or improper site preparation
or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the implied
warranties of merchantability and fitness for any particular purpose.
The remedies provided herein are the Buyer's sole and exclusive remedies. Omnitron
shall not be liable for any direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal theory.
, miConverter
, NetOutlook
, OmniLight
®
TM
®
, OST
TM
Page 2
,
®
and
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RuggedNet 10GMGPoEBT/Si and is the answer not in the manual?

Questions and answers

Summary of Contents for Omnitron Systems RuggedNet 10GMGPoEBT/Si

  • Page 1 Omnitron Systems Technology, Inc. The following trademarks are owned by Omnitron Systems Technology, Inc.:...
  • Page 2: Product Overview

    Product Overview Directive) of the European Community directive 2012/19/EU on waste electrical and The RuggedNet 10GMGPoEBT/Si are unmanaged multi-gigabit Ethernet switches electronic equipment (WEEE) which, together with the RoHS Directive 2015/863/ EU, for electrical and electronic equipment sold in the EU after July 2019. Such...
  • Page 3: Installation Procedure

    Installation Procedure SW1: Switch Mode - “Normal/Directed Switch” 1) Configure DIP-switches The module supports Normal or Directed Switch Mode. 2) Installing the Module The modes are described with MAC learning enabled. When MAC learning is disabled, unicast packets are forwarded to all ports. 3) Apply DC Power Switch Mode 4) Connect Cables...
  • Page 4: Installing The Module

    SW4 and SW5: PoE Forced - “Disabled/Enabled” SW8: L2CP - “L2CP Tunnel/Discard” These DIP-switches configure the PoE ports for normal or forced mode per the When this DIP-switch is in the LEFT “L2CP Tunnel” position (factory default), all table below. L2CP frames will be tunneled through the module.
  • Page 5: Apply Dc Power

    3) Apply DC Power This module is intended for installation in restricted access areas. (“Les matériels sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT”). A restricted access area can be accessed only through the use of a special key, or other means of security.
  • Page 6: Connect Cables

    4) Connect Cables 4) Verify Operation Insert the appropriate fiber or copper transceiver into the SFP receptacle on Verify the module is operational by viewing the LED indicators. the front of the module (see the SFP Data Sheet 091-17000-001 for supported Power LED Indicators Gigabit transceivers or 091-17400-001 for supported 10G transceivers).
  • Page 7: Specifications

    Specifications 10/100/1000 RJ-45 Port LED Indicators Legend Indicator Description RuggedNet ® 10GMGPoEBT/Si Description Unmanaged Industrial IEEE 802.3bt 10Gigabit Port not linked Multi-Gigabit/Multi-Rate Ethernet Switch Link Green - ON Port linked at the speed indicated by the Rate LED IEEE 802.3, 802.3bz, Green - Blinking at 10Hz Port is linked and transmitting or receiving data Standard Compliances...
  • Page 8: Customer Support Information

    (949) 250-6510 EN 60950-1, CAN/CSA C22.2 No. 62368-1-14, Fax: (949) 250-6514 CAN/CSA C22.2 No. 60950-1, CE Mark, UKCA Address: Omnitron Systems Technology, Inc. EMC: EN 55032/24 CE Emissions/Immunity, IEC 61000-6-4 Industrial Emissions, 38 Tesla Regulatory IEC 61000-6-2 Industrial Immunity Compliances...

Table of Contents