38 Tesla, Irvine, CA 92618 USA
Phone: (949) 250-6510; Fax: (949) 250-6514
General and Copyright Notice
This publication is protected by U.S. and international copyright laws. All rights
reserved. The whole or any part of this publication may not be reproduced, stored
in a retrieval system, translated, transcribed, or transmitted, in any form, or by
any means, manual, electric, electronic, electromagnetic, mechanical, chemical,
optical or otherwise, without prior explicit written permission of Omnitron Systems
Technology, Inc.
The following trademarks are owned by Omnitron Systems Technology, Inc.:
FlexPoint
, FlexSwitch
, HybridNID
TM
TM
OmniLight
, OmniConverter
, RuggedNet
®
®
OST
and the Omnitron logo.
TM
All other company or product names may be trademarks of their respective owners.
The information contained in this publication is subject to change without notice.
Omnitron Systems Technology, Inc. is not responsible for any inadvertent errors.
Warranty
This network product and the included AC/DC power adapter are warranted to the
original purchaser (Buyer) against defects in material and workmanship for a period
of two (2) years from the date of shipment. The warranty for the network product
(excluding the AC/DC power adapter) can be extended to five (5) years by registering
the product at www.omnitron-systems.com/support within ninety (90) days from the
date of shipment. During the warranty period, Omnitron will, at its option, repair or
replace a product which is proven to be defective with the same product or with a
product with at least the same functionality.
For warranty service, the product must be sent to an Omnitron designated facility,
at Buyer's expense. Omnitron will pay the shipping charge to return the product
to Buyer's designated US address using Omnitron's standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to product malfunctions resulting from
improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-
supplied equipment, Buyer-supplied interfacing, unauthorized modifications or
tampering with equipment (including removal of equipment cover by personnel not
specifically authorized and certified by Omnitron), or misuse, or operating outside
the environmental specification of the product (including but not limited to voltage,
ambient temperature, radiation, unusual dust, etc.), or improper site preparation
or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the implied
warranties of merchantability and fitness for any particular purpose.
The remedies provided herein are the Buyer's sole and exclusive remedies. Omnitron
shall not be liable for any direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal theory.
, iConverter
, miConverter
, NetOutlook
®
®
TM
, Omnitron Systems Technology, Inc.
®
Page 2
,
®
,
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OmniConverter 10G/Sx 6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Omnitron Systems OmniConverter 10G/Sx 6

  • Page 1 Omnitron Systems Technology, Inc. The following trademarks are owned by Omnitron Systems Technology, Inc.:...
  • Page 2: Product Overview

    OmniConverter 10G/Sx ® Environmental Notices The equipment covered by this manual must be disposed of or recycled in User Manual accordance with the Waste Electrical and Electronic Equipment Directive (WEEE Product Overview Directive) of the European Community directive 2012/19/EU on waste electrical and electronic equipment (WEEE) which, together with the RoHS Directive 2015/863/ The OmniConverter 10G/Sx is an unmanaged compact 10Gigabit Ethernet switch EU, for electrical and electronic equipment sold in the EU after July 2019.
  • Page 3: Installation Procedure

    Installation Procedure The modes are described with MAC learning enabled. When MAC learning is disabled, unicast packets are forwarded to all ports. 1) Configure DIP-switches Function 2) Installing the Module DOWN DOWN Switch Mode (factory default) 3) Apply Power DOWN Directed Switch Mode 4) Connect Cables DOWN...
  • Page 4 Dual Device Mode When configured for Dual Device Mode, the module is configured as two logically independent Layer 2 switches. On models with 4 RJ-45 user ports, Port F1 is associated with ports P1 and P2 and Port F2 is associated with ports P3 and P4. On models with 8 RJ-45 user ports, Port F1 is associated with ports P1 - P4 and Port F2 is associated with ports P5 - P8.
  • Page 5: Rack Mounting

    Rack Mounting The 6 Port 10G/Sx requires +12 to +57VDC inclusive of tolerances( 0.86A @ 12VDC max rated power). The 10 Port 10G/Sx requires +12 to +57VDC inclusive of The module can be rack mounted using the optional Rack Mount Shelf (8260-0). tolerances (0.94A @ 12VDC max rated power).
  • Page 6: Connect Cables

    4) Connect Cables Insert the SFP/SFP+ transceiver into the SFP receptacle on the front of the module (see the SFP Data Sheet 091-17000-001 for supported Gigabit transceivers or 091-17400-001 for supported 10G transceivers). NOTE: The release latch of the SFP fiber transceiver must be in the closed (up) position before insertion.
  • Page 7: Specifications

    Specifications RJ-45 User Ports LED Indicators OmniConverter 10G/Sx ® Legend Indicator Description Description 10/100/1000BASE-T with 1G or 10G Uplinks No link Unmanaged 6 or 10 Port 10Gigabit Ethernet Switch 4 Port Standard Compliances IEEE 802.3 Green - ON Port linked at 100Mbps Environmental REACH, RoHS and WEEE Green - Blinking at 10Hz...
  • Page 8: Customer Support Information

    Regulatory Compliances EMI: CISPR 32, FCC 47 Part 15 Subpart B Class A (Pending) Address: Omnitron Systems Technology, Inc. EMS: IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m, 38 Tesla IEC 61000-4-4 EFT: Power: 1 kV;...

This manual is also suitable for:

Omniconverter 10g/sx 10

Table of Contents