Lincoln Electric 11141 Service Manual page 72

Table of Contents

Advertisement

F-26
6
3
TEST PROCEDURE
1. Remove input power to the Power Wave
355M/405M.
2. Using the 3/8" nut driver, remove the case
top.
3. Perform
the
Procedure.
4. Locate the Power Board and plugs J42 and
J43. Do not remove plugs or leads from
the Power Board. Refer to Figure F.9.
5. Carefully apply input power to the Power
Wave
®
355M/405M.
WARNING
ELECTRIC SHOCK can kill.
High voltage is present when
input power is applied to the
machine.
TROUBLESHOOTING AND REPAIR
POWER BOARD TEST (CONTINUED)
FIGURE F.5 – POWER BOARD TEST
J42
J41
4
3
5
4
2
1
2
1
J42
Capacitor
Discharge
POWER WAVE
J43
12 11 10 9
6
5
4 3
J43
J41
®
6. Turn on the Power Wave
Carefully test for the correct voltages at the
Power Board according to Table F.4.
7. If either of the 40 VDC voltages is low or not
present at plug J41, perform the DC Bus PC
Board Test. See the Wiring Diagram. Also
perform the T1 Auxiliary
Test.
8. If any of the DC voltages are low or not pre-
sent at plugs J42 and/or 43, the Power
Board may be faulty.
9. Install the case top using the 3/8" nut driver.
®
355M/405M
F-26
8 7
2
1
®
355M/405M.
Transformer

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power wave 405mPower wave 355m114891114211490

Table of Contents