A-6
Enable the voltage sense leads as follows:
TABLE A.1
Process Electrode Voltage
Sensing 67 lead *
GMAW 67 lead required
GMAW-P 67 lead required
FCAW
67 lead required
GTAW
Voltage sense at studs
GMAW Voltage sense at studs
SAW
67 lead required
CAC-C Voltage sense at studs
* The electrode voltage 67 sense lead is integral to the
control cable to the wire feeder.
Work Voltage Sensing
The standard POWER WAVE
the work stud (work sense lead disabled)
For processes requiring work voltage sensing, connect
the (21) work voltage sense lead (K940) from the
Power Wave
work sense lead receptacle to the work
®
piece. Attach the sense lead to the work piece as close
to the weld as practical, but not in the return current
path. Enable the work voltage sensing in the Power
Wave
®
as follows:
WARNING
• Do not touch electrically live parts or
electrodes with your skin or wet
clothing.
• Insulate yourself from the work and
ground.
• Always wear dry insulating gloves.
1. Turn off power to the power source at the disconnect
switch.
2. Remove the wrap around cover from the power
source.
3. The control board is on the center assembly facing
the case front. Locate the 8-position DIP switch and
look for switch 8 of the DIP switch.
4. Using a pencil or other small object, slide the switch
to the OFF position if the work sense lead is NOT
connected. Conversely, slide the switch to the ON
position if the work sense lead is present.
O
N
1
2
3
4
INSTALLATION
Work Voltage
Sensing 21 lead
21 lead optional
21 lead optional
21 lead optional
Voltage sense at studs
Voltage sense at studs
21 lead optional
Voltage sense at studs
®
355M/405M default to
5
6
7
8
POWER WAVE
5. Replace the wrap around and screws. The PC board
will "read" the switch at power up, and configure the
work voltage sense lead appropriately.
ELECTRODE VOLTAGE SENSING
Enabling or disabling electrode voltage sensing is
automatically configured through software. The 67
electrode sense lead is internal to the cable to the wire
feeder and always connected when a wire feeder is
present.
PF10M feeder has user preference features to select
voltage senses temporarily for testing sense leads.
CAUTION
Important: The electrode polarity must be config-
ured at the feed head for all semi-automatic
processes. Failure to do so may result in extreme-
ly high welding outputs.
------------------------------------------------------------------------
POWER WAVE
®
TO SEMI-AUTOMATIC
POWERFEED WIRE FEEDER INTERCON-
NECTIONS
The POWER WAVE
355M/405M and semi-automatic
®
Power Feed family communicate via a 5 conductor
control cable (K1543). The control cable consists of
two power leads, one twisted pair for digital communi-
cation, and one lead for voltage sensing. The cables
are designed to be connected end to end for ease of
extension. The output receptacle on the POWER
WAVE
®
405M is on the case front. The input receptacle
on the Power Feed is typically located at the back of
the feeder, or on the bottom of the user interface.
Due to the flexibility of the platform the configuration
may vary. The following is a general description of the
system. For specific configuration information, consult
the semi-automatic Power Feed instruction manual.
®
355M/405M
A-6