Lincoln Electric 11141 Service Manual page 11

Table of Contents

Advertisement

A-3
TECHNICAL SPECIFICATIONS -
Product
Ordering Input AC
Name
Information Voltage
Power
200-208 /
Wave
K 2152-2
220-240/
405
380-415/
3/50/60
60/50 Hz 275A / 31V /100%
* Overall Length Including Handle, 21.6" (549mm) without handle.
Recommended Fuse Sizes Based On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Voltage
Phases
200
3
220
3
380
3
400
3
415
3
Voltage
Phases
31Volts(100%)
200
1
Not Recommended Not Recommended
220
1
380
1
400
1
415
1
1. Not rated is indicated by 4-x's in the box on the rating plate
2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Select the output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE
CURRENT
100%
275
60%
350
INSTALLATION
POWER WAVE
INPUT AC VOLTAGE & DC OUTPUT
Rated DC Output
Amps/Volts/Duty Cycle
350A / 34V / 60%
3 Phase
320A / 33V / 60%
1 Phase
1 Phase
300A / 32V / 100%
3 Phase
POWER WAVE
®
Output
300Amps@
350Amps@
32Volts(100%)
34Volts(60%)
41
48
37
48
23
28
22
27
22
26
275Amps@
320Amps@
33Volts(60%)
64
82
44
55
40
50
38
48
LENGTH UP 61m (200 FT)
POWER WAVE
405
®
Output
Weight
Range
with Cord
(continuous)
AMPS
5-425
(37.4 kg)
405 INPUT CURRENT
Recommended
Line Cord
Size mm
2
16
16
10
10
10
Line Cord
Size mm
2
---
20
16
10
10
1/0
1/0
®
355M/405M
Dimensions
HxWxD
14.7"x12.5"x
27.8"*
86.5lbs
(373x318x
706*)mm
* Includes
handles
Size Fuse Size
80A
Note 2
80A
Note 2
50A
50A
50A
Fuse Size
-----
Note 1
125A
Note 2
80A
Note 2
80A
80A
61-76m (200-250 FT)
1/0
2/0
A-3
Notes
Notes

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power wave 405mPower wave 355m114891114211490

Table of Contents