aluminum or precision-cast stainless steel.
b) The housing features detachable circular protective covers on
the front and rear sides, with fixed screws on the front side to
prevent the protective cover from loosening or detaching.
c) Based on the model, the front cover (1) can be designed as a
viewing window, allowing direct reading of measured values
from the LCD display (2).See Figure 29 for details.
d) Limiting screw: Prevent entanglement with the measurement
unit associated with the electronic device.
e) The interior of the rear cover (9) is the electrical terminal
compartment. See Figure 23 for details.
f)The cable entry gland (3) for the electrical terminal compartment
is on one side: the left or right entry can be used, and any
unused conduit are sealed with stainless steel plug (4). The
cable entry gland (3) and stainless steel plug (4) are provided as
accessories and should be installed by first removing the plastic
protective cap and then assembling the accessories.
g) The stainless steel nuts for the clamp (6) are provided as
accessories and should be assembled by removing the
corresponding plastic protective cap based on the requirements.
h) Under the nameplate (8), three buttons for local operation are
visible.
4.3 Installation
The transmitter housing can be rotated approximately 300° relative to
the sensor (see outline construction and overall dimensions), allowing
it to be fixed in any position without affecting performance and internal
wiring.
When rotating the housing, it is imperative not to forcibly
rotate the sensor part. Instead, use a 2mm hex wrench to loosen the
9