Problem and alarm code
The programme does not start.
The appliance does not fill with water.
•
The indicator
flashes 1 time intermit‐
tently.
•
Acoustic signal sounds 1 time intermittently.
The appliance does not drain the water.
•
The indicator
flashes 2 times intermit‐
tently.
•
Acoustic signal sounds 2 times intermittent‐
ly.
The anti-flood device is on.
•
The indicator
flashes 3 times intermit‐
tently.
•
Acoustic signal sounds 3 times intermittent‐
ly.
Malfunction of the water level detection sensor.
•
The indicator
flashes 4 times intermit‐
tently.
•
Acoustic signal sounds 4 times intermittent‐
ly.
Malfunction of the wash pump or the drain
pump.
•
The indicator
flashes 5 times intermit‐
tently.
•
Acoustic signal sounds 5 times intermittent‐
ly.
The temperature of the water inside the appli‐
ance is too high or malfunction of the tempera‐
ture sensor occurred.
•
The indicator
flashes 6 times intermit‐
tently.
•
Acoustic signal sounds 6 times intermittent‐
ly.
Possible cause and solution
•
Make sure that the appliance door is closed.
•
If the delay start is set, cancel the setting or wait for the
end of the countdown.
•
The appliance recharges the resin inside the water soften‐
er. The duration of the procedure is approximately 5 mi‐
nutes.
•
Make sure that the water tap is open.
•
Make sure that the pressure of the water supply is not too
low. For this information, contact your local water authority.
•
Make sure that the water tap is not clogged.
•
Make sure that the filter in the inlet hose is not clogged.
•
Make sure that the inlet hose has no kinks or bends.
•
Make sure that the sink spigot is not clogged.
•
Make sure that the interior filter system is not clogged.
•
Make sure that the drain hose has no kinks or bends.
•
Close the water tap.
•
Make sure that the appliance is correctly installed.
•
Make sure the baskets are loaded as instructed in the user
manual.
•
Make sure that the filters are clean.
•
Switch the appliance off and on.
•
Switch the appliance off and on.
•
Make sure that the temperature of the inlet water does not
exceed 60°C.
•
Switch the appliance off and on.
ENGLISH
21