Recommended Processes And Equipment; Machine Capability; Limitations - Lincoln Electric IDEALARC CV-300 Service Manual

Hide thumbs Also See for IDEALARC CV-300:
Table of Contents

Advertisement

B-2
Magnum Twist-Mate output receptacles.
Single MS-type (14-pin) connection for wire
feeder.
Solid state controls, with line voltage compen-
sation.
Optional remote control capability.
Simple controls - easy to operate.
Electronic and thermostatic protection from
overloads.
Submersion dipping of assembled trans-
former, choke, and rectifier in special seal-
ing/insulating material that gives extra protec-
tion against moisture and corrosive atmos-
pheres.
Microprocessor based Control PC Board has
built-in diagnostic routines.
Compact size, requires only 19" x 26"of
space.
Modular construction for easy servicing.
Recessed panels protect output terminals and
controls.
Large safety margins and protective circuits
protect rectifiers from transient voltages and
high currents.
RECOMMENDED PROCESSES AND
EQUIPMENT
The CV-300 is capable of solid wire welding within the
rated output capacity of the machine. It is capable of
welding with the following flux-cored wires:
NR-152
NR-211
NS-3M
NR-203 Ni 1%
Outershields 70 and 71
The CV-300 is recommended for use with the follow-
ing wire feeders:
LN-7
LN-742
OPERATION
LN-25
Duty Cycle
(10-Minute
Period)
100%
60%

MACHINE CAPABILITY

LIMITATIONS

The CV-300 is intended only for use with the following
FCAW electrodes:
NR-152
NR-211
NR-203 Ni 1%
NS-3M
Outershield 70 and 71
The machine has been designed primarily for the
GMAW process. The results with FCAW electrodes
other than those listed may or may not be satisfacto-
ry.
IDEALARC CV-300
Amps.
Volts
300
32
400
36
B-2