Keypad Security Settings
The keypad can be locked to prevent unauthorised adjustment of the appliance and it's operating temperature.
When the keypad is locked no adjustments can be made using the keypad and icon 'f' will be displayed.
To lock or unlock the keypad press and release button 2 for 3 seconds and the display will show 'SP' . Release the button and then press button 2 once and the display
will show 'Loc' . Press button 1 to display the current keypad lock status. Adjust using button 2 and button 4 to set the value to 'Yes' to lock the keypad and 'no' to
unlock the keypad. Press button 1 to save the new value. If button 1 is not pressed the new value will not be stored. The display will resume normal operation after
30 seconds or if button 3 is pressed.
Defrost
The appliance has an automatic defrost function and will defrost periodically each day without any user intervention.
This process is normal and does not affect product stored in the appliance. During defrost the appliance can be used as
normal.
To start a defrost manually press and hold button 1 for 5 seconds. This will turn off the appliance. When this happens
do not release the button and after 2 more seconds the display will indicate a defrost has commenced (dEF is briefly
displayed) and the button can be released. The appliance set point temperature will be displayed during defrost and icon
'g' will flash to indicate a defrost is in progress.
The defrost will operate for it's full duration, it is not possible to cancel a defrost when it has started.
Door Lock
To lock the door insert the key and turn 90°, turn in the opposite direction to unlock.

Internal Light

The lights are operated by pressing button 5. Press once to turn the lights on or off.
Keypad Sounds
If the user does not require the keypad to indicate with a sound when a button is pressed this can be turned off. Press
and hold button 2 for 3 seconds until the display shows 'SP' . Press button 2 until the display shows 'biP' . Press button 1 to
display the current value. 'Yes' indicates keypad sounds are active and 'no' indicates keypad sounds are not active. Select
the value required and press button 1 to save the new value. If button 1 is not pressed the new value will not be stored.
Exit with button 3.

Alarms Notification

If an alarm condition occurs the appliance will indicate this with an audible signal, by illuminating icon 'a' and displaying a fault code from the list in
the 'Troubleshooting' section of this manual. The audible notification can be muted temporarily by pressing button 1. While the fault is still present
icon 'a' will continue to be illuminated and the display will cycle between the fault code and the appliance temperature.
6