Floor Construction - Kohler Englefield 707630A-NA Installation Instructions Manual

Tile over stainless steel shower tray

Advertisement

TILE OVER
B) FLOOR CONSTRUCTION
Ensure that is enough space under the floor to install the tray, the waste fitting and the
plumbing with an adequate fall of 1.5° (25mm/metre) and continuous flow without bends
and restrictions for 1.5 metres from the trap outlet.
145
C) WALL CONSTRUCTION - TIMBER FRAME:
Wall Framing:
Attention: Englefield strongly recommends fixing the shower door/return panel
wall retainers to double studs for all installation types (as shown).
Check if additional nog is required to support top bracing brackets (depending on the
shower model).
Build additional solid nog perimeter of framing to support the tray and bottom fixing of
linings. Ensure that the walls are plumb.
A
Double
studs
Timber Floor Installation:
When installed on a timber floor, the floor board should be supported at not greater
than 400 mm centres and the waste connection cut-out kept to a minimum.
Concrete Floor Installation:
When installed on a concrete slab floor, chases or channels left for plumbing must be
completely backfilled.
1598330-A02-A
Stainless Steel Trays
B
(Fig. 1)
Solid nog
perimeter
March 2024
INSTALLATION INSTRUCTIONS
FLOOR LEVEL
1.5°
SHOWER TRAY
900 X 900
1000 X 1000
Page 3
C
D
900
900
1000
1000
englefield.co.nz