Page 1
ELECTRONIC IGNITION FIRE PIT INSERT TOR-PENTA25EI TOR-36X14SSEI EI Series On/Off Models Installation & Operation Instructions 860-EI ON/OFF...
Page 2
This is a Safety Alert Symbol When you see this symbol on the fire pit insert, or in this manual, look for one of the following signal word panels alerting you to the potential for personal injury, death, or major property damage. WARNING: For Outdoor Use Only.
Table of Contents Important Safety Information ....................... 3 Technical Support ........................3 Symbol Legend ......................... 4 Important Safety Information for Installers ................5 Important Safety Information for End-Users ................6 Product Features and Parts List ....................7 Selecting the Fire Pit Location ..................... 8 Overhead Structures and Sidewall Clearance Requirements ...........
Important Safety Information • Hearth Products Controls Company recommends that our products are installed INSTALLER: by professionals locally licensed by the authority having jurisdiction in gas piping. Leave this manual with All installation instructions must be followed to ensure proper performance and the appliance.
Important Safety Information Symbol Legend This is a Safety Alert Symbol When you see this symbol on the fire pit insert, or in this manual, look for one of the following signal word panels alerting you to the potential for personal injury, death, or major property damage.
• If not using the supplied flex line, ensure any flex line that may be used from the permanent main fuel supply to the product is rated to the stated max BTU of the product and certified to ANSI Z21.75*CSA 6.27. • The EI Series is not for use with small LP Tanks and must utilize permanent fixed piping for fuel supply.
• 12 VACS (313-PS1, 313-PS3, 313-PS5 Models) HPC recommends that both 24 and 12 VAC fire pits when being wired to not be daisy chained in line. Each fire pit should have its own dedicated line. A Class II 24 and 12 VACS, 4-amp, 100 W transformer must be used to power the fire pit and be able to be switched on and off from a remote location to allow for easy access or emergency.
Product Features and Parts List Product Features Burner *With optional SST™ Torpedo Ignition System Blowout Box EI On/Off Control Box Parts List • Fire Pit Insert • Gas Input Flex Line – 24" • Installation and Operation Instructions...
NOTE: All fire pits and systems are designed and intended for outdoor use only. It is recommended that material such as granite, marble or other dense stone be kept away from heat and especially flame due to risk of cracking. HPC is not responsible for damage resulting from failure to follow these recommendations.
Overhead Structures and Sidewall Clearance Requirements It is important to review the clearance requirements below for any type of overhead structure such as pergola, roof, overhang, screens, arbor, etc. or a sidewall to ensure that the distances are met. Figures 4.1 and 4.2. Table 4.1 –...
Page 12
Overhead Structures and Sidewall Clearance Requirements...
The manufacturer is not responsible for the damage. • The enclosure must be constructed on a stable surface and be level. HPC recommends the use of the installation collar (optional) that may be mortared into or sandwiched between layers of the enclosure.
Page 14
36 square inches or more of free area are acceptable for large units to prevent overtempts to the electronics. - Ventilation along the bottom of the enclosure allows for a full open design is acceptable as well. HPC unfinished enclosures reflect this ventilation.
Adding Approved Media Fuel line • A fire pit must have a gas shutoff on the outside of the exterior of the fire pit to allow for emergency shut off and maintenance. The gas shutoff should not be used to adjust flame height. •...
Page 16
Installing the Fire Pit For Penta Burner inserts, the flame will be smaller with no media on the burner. 1. Turn off the fire pit and allow it to cool. 2. Apply media as described in Section 7, Adding Approved Media. When filling the pan with lava rock and/or decorative glass, the instructions in Section 7 must be followed.
Adding Approved Media WARNING FOR GLASS MEDIA USAGE WITH LP GAS - THE UNIT MUST BE TESTED WITH MEDIA OVER BURNER FOR CONFIRMATION OF NO BACK PRESSURE CREATING GAS TO LEAK OUT OF AIR MIXER VENTURI HOLES. THIS MAY HAVE TO BE DONE PRIOR TO PLACING IN ENCLOSURE IF NO ACCESS DOOR. WARNING FOR GLASS MEDIA USAGE WITH LP GAS - WHEN USING APPROVED DECORATIVE GLASS TO COVER BURNER APPLY ONLY ENOUGH TO HIDE BURNER.
Page 18
Adding Approved Media Application of Approved Media Please follow the instructions below to add the final addition to your fire pit. Particular attention needs to be paid to the pilot assembly area. Incorrect media installation will cause the pilot flame to suffocate and turn off pit or delay main burner ignition.
Operating the Fire Pit • Before use, be sure to test all gas connections for leaks. Do not use a fire pit if there is any evidence of leaking gas. If leaking gas is suspected, turn off the main gas supply and repair it immediately. •...
Page 20
Operating the Fire Pit Start-up DANGER Initial Start-up: Several “ON/OFF” cycles may be If you smell gas: necessary to purge air in gas lines after system Shut off gas to appliance. installation. Fire pit will lockout after 15 attempts to light Extinguish any open flame.
Maintaining the Fire Pit • Any guard or protective device removed for servicing must Service be replaced prior to operating the fire pit. We suggest that our products • We suggest that our products be serviced annually by a be serviced by a professional professional certified in the US by the National Fireplace certified in the US by the Institute (NFI) as NFI Gas Specialists.
Troubleshooting Service Table 10.1 and 10.2, below indicates some potential causes and countermeasures to the symptoms We suggest that our products be indicated in bold type. Please contact your retailer serviced by a professional certified in or certified technician for service and repair. the US by the National Fireplace •...
Page 23
Troubleshooting 12v units Error Number & Problem Possible Causes Solution Description New install – May take several attempts Air in gas line No gas flow – Gas not ON or Confirm gas is ON upstream Debris in line – insulation, dirt, plastic, etc. line obstruction Pilot orifice dirty or clogged Remove orifice and clean (Section 9)
For a complete list of accessories, visit www.hpcfire.com Figure 12.1 – Fire pit cover Replacement Parts Please contact your dealer for parts – if unsure please contact HPC or visit our website at www.hpcfire.com and we will be happy to help you. Pilot Assembly...
4) Stainless Steel Pan, Valve Box: Commercial-1 year; Residential-5 years Warranty commences from the date of original sale / shipment from HPC FOB Dayton, Ohio. This warranty is for parts and in-house (HPC) labor. The defective product must be sent back to HPC with a Return Merchandise Authorization (RMA) issued by HPC for that specific product and any other additional information for the nature of the defect or warranty claim.
Need help?
Do you have a question about the EI Series and is the answer not in the manual?
Questions and answers