    Contents Locking cylinder (Z4) 3061 (Manual) 2 / 69 Contents Intended use.............................. 5 General safety instructions ........................ 6 Product specific safety notices...................... 9 General.................................  12 Product description ............................ 12 Locking cylinder design.......................... 13 Half cylinder design ............................ 14 Opening and locking from the outside.................... 14 Opening and locking from the inner side ....................
  • Page 3 Contents Locking cylinder (Z4) 3061 (Manual) 3 / 69 Programming the locking cylinder ...................... 24 Installation variants............................ 24 6.3.1 Installation............................ 24 6.3.2 Fitting an anti-panic cylinder.................... 28 6.3.3 Installation of SKG/VdS cylinders .................. 31 6.3.4 Half Cylinder DK/MR........................ 32 6.3.5 Installing Swiss Round...................... 40 6.3.6 Magnetic plate for DoorMonitoring ..................
  • Page 4 Contents Locking cylinder (Z4) 3061 (Manual) 4 / 69 Declaration of conformity........................ 66 Help and other information ........................ 67...
  • Page 5: Intended Use

    (Manual) 5 / 69 1 Intended use Digital SimonsVoss Locking Cylinder 3061 are installed in designated door locks, such as DIN mortise locks, to integrate them into a digital locking system. The digital Locking Cylinder 3061 may only be used for its intended purpose in a designated door locking device.
  • Page 6: General Safety Instructions

    Blocked access Access through a door may stay blocked due to incorrectly fitted and/or in- correctly programmed components. SimonsVoss Technologies GmbH is not liable for the consequences of blocked access such as access to in- jured or endangered persons, material damage or other damage!
  • Page 7 2. General safety instructions Locking cylinder (Z4) 3061 (Manual) 7 / 69 PRUDENCE Fire hazard posed by batteries The batteries used may pose a fire or burn hazard if handled incorrectly. 1. Do not try to charge, open, heat or burn the batteries. 2.
  • Page 8 Only trained personnel may install and commission the product.  Incorrect installation SimonsVoss Technologies GmbH accepts no liability for damage caused to doors or compon- ents due to incorrect fitting or installation. Modifications or further technical developments cannot be excluded and may be implemented without notice.
  • Page 9: Product Specific Safety Notices

    1. Only use the anti-panic version of the locking cylinder in locks for which the locking cylinder is expressly approved. 2. Please refer to the documentation of the respective lock manufacturer. 3. Contact SimonsVoss Technologies GmbH for further information on this Help and other information [  67]...
  • Page 10 3. Product specific safety notices Locking cylinder (Z4) 3061 (Manual) 10 / 69 Mechanical damage to the thumb turn as a result of obstacles If the thumb turn can knock against the wall or other objects as a result of the installation situ- ation, it may become damaged.
  • Page 11 3. Product specific safety notices Locking cylinder (Z4) 3061 (Manual) 11 / 69 Difficulty of operation of the lock due to stiff latch or bolt If the latch or bolt of the mortice lock are stiff, the closing cylinder will also be stiff. Check that the latch or the bolt of the mortice lock are free-moving.
  • Page 12: General

    12 / 69 4 General 4.1 Product description The SimonsVoss Digital Locking System 3060 is an electronic version of a mechanical locking system with the functions of a typical access control system. Digital Locking Cylinder 3061 and the digital half cylinder are a main...
  • Page 13: Locking Cylinder Design

    An intelligent battery warning system also increases reliability. The SimonsVoss system elements are not configured before delivery from the factory. They are first assigned to a locking system during initial programming.
  • Page 14: Half Cylinder Design

    4. General Locking cylinder (Z4) 3061 (Manual) 14 / 69 4. Drilling protection 5. Outer thumb-turn 4.3 Half cylinder design 1. Actuator 2. Electronics 3. Batteries 4. Thumb-turn 4.4 Opening and locking from the outside With freely rotating locking cylinders (FD) The outer and inside thumb-turn rotate freely when not activated in the freely rotating Locking Cylinder 3061, meaning it is not possible to open or lock the door without a valid ID medium.
  • Page 15: Opening And Locking From The Inner Side

    4. General Locking cylinder (Z4) 3061 (Manual) 15 / 69 NOTE If the user has an ID medium which is not authorised for use at that particu- lar moment due to the time zone plan, a single audible signal will sound. The cylinder will not engage, so the outer or inside thumb-turn continues to rotate freely and the user cannot open the door.
  • Page 16: Versions

    5. Versions Locking cylinder (Z4) 3061 (Manual) 16 / 69 5 Versions Different versions of the digital Locking Cylinder 3061 are offered to cover the different needs of the market. The different versions are indicated by a code. The different versions can be combined: LOCKING CYLIN- ABBREVIATION DESIGNATION...
  • Page 17: Fd Version (Standard)

    5. Versions Locking cylinder (Z4) 3061 (Manual) 17 / 69 Refer to the current product catalogue to see which particular versions can be combined with one another. Locking cylinders are also supplied in different profiles to satisfy differences in different regions: PROFILE LOCKING CYLINDER HALF CYLINDER...
  • Page 18: Version For Steel And Fire Retardant Doors

    5. Versions Locking cylinder (Z4) 3061 (Manual) 18 / 69 TLocking Cylinder 3061 can be programmed in such a way that authorized transponders are only authorized for access at specific times. For G1, there are 5 (+1) time zone groups available per area (e.g. outer perimeter) within the different time zone schedules while G2 has 100 (+1) such groups.
  • Page 19: Skg Or Vds Versions (Sz)

    5. Versions Locking cylinder (Z4) 3061 (Manual) 19 / 69 5.9 SKG or VdS versions (SZ) The Locking Cylinder 3061 is optionally also available as a VdS cylinder. The additional mechanical security features ensure that VdS Classes AZ and BZ or Class SKG*** are achieved. These versions cannot be combined with the brass and WP versions.
  • Page 20: Ap2 Version

    5. Versions Locking cylinder (Z4) 3061 (Manual) 20 / 69 1. Inside thumb-turn 2. Recessed grip ring 3. Battery replacement key 4. Outside thumb-turn The following aspects should be taken into consideration for doors along rescue routes which have been installed after April 1, 2003 (exit devices as per DIN EN 179 or DIN EN 1125): All Locking Cylinder 3061 models may be used for all exit devices where their approval states that the Locking Cylinder 3061 has no impact on the lock's function.
  • Page 21: Co Version

    5. Versions Locking cylinder (Z4) 3061 (Manual) 21 / 69 Installation is the same as with the regular Locking Cylinder 3061. The following aspects should be taken into consideration for doors along rescue routes which have been installed after April 1, 2003 (exit devices as per DIN EN 179 or DIN EN 1125): All Locking Cylinder 3061s may be used with all closures whose approval states that the Locking Cylinder 3061 has no effect on the function of the lock.
  • Page 22: Wp Version (Hz/Co/Ap)

    5. Versions Locking cylinder (Z4) 3061 (Manual) 22 / 69 This version is available from a length of 30-35 mm and as .FD, .ZK, .MS and .FH models. 5.14 WP version (HZ/CO/AP) The electronic thumb-turn is sealed in the WP version of the half, comfort and anti-panic cylinders, thus providing an increased protection rating of IP66.
  • Page 23: Extra Lengths

    5. Versions Locking cylinder (Z4) 3061 (Manual) 23 / 69 5.20 Extra lengths All double knob cylinders are available with an overall length of up to 140 mm or a maximum of 90 mm on one side. Longer lengths can be supplied on request.
  • Page 24: Installation Instructions

    6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 24 / 69 6 Installation instructions 6.1 General instructions When installing the digital Locking Cylinder 3061, ensure that there are no sources of low-frequency radio interference in the surrounding area. The profile cylinder housing should be fitted flush in outside areas; it should project a maximum of 3 mm and a profile cylinder escutcheon or security fitting should be installed if necessary.
  • Page 25 6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 25 / 69 ü PH2 SCREWDRIVER (or Z4.DM.SCREWDRIVER for DoorMonitoring variants) ü Installation or battery key Cylinder programmed. ü 1. Remover the thumb-turn (CO: inside, FD: outside). 2. Insert the cylinder into the door (CO: from outside; FD: from inside). 3.
  • Page 26 6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 26 / 69 4. Replace the thumb-turn. 5. Turn the thumb-turn anticlockwise until it locks into the indents in the flange. To do so, turn the locking disc back using the installation key if neces- sary.
  • Page 27 6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 27 / 69 8. Hold the thumb turn firmly and carefully turn the installation key about 30° counter-clockwise. The locking disc will click. 9. VdS/SKG variants only: Screw the hex screw into the thumb-turn tightly.
  • Page 28: Fitting An Anti-Panic Cylinder

    6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 28 / 69 6.3.2 Fitting an anti-panic cylinder 1. Inside thumb-turn 2. Recessed grip ring 3. Battery replacement key 4. Outside thumb-turn The locking cam is always in a pre-defined position in the AP cylinder when disengaged.
  • Page 29 6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 29 / 69 Violent action on the thumb turn Don't strike the thumb turns when installing the cylinder. 6.3.2.1 Removing the inside thumb-turn Loosen the inside thumb-turn's threaded pin (see diagram above) using an Allen key (1.5 mm).
  • Page 30 6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 30 / 69 U section: No restore force on the cam R section: Restore force section towards U section Top dead point in deadbolt throw - no restore force on O section: the cam Top threshold section Lower threshold section...
  • Page 31: Installation Of Skg/Vds Cylinders

    6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 31 / 69 repeated after the fault has been eliminated. A fastening screw which has been tightened too firmly acts as a brake on the restoring force mechanism. 4. Lock the door and check that the locking device functions correctly by pressing the door fitting or panic bar in the direction of escape.
  • Page 32: Half Cylinder Dk/Mr

    6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 32 / 69 3. Place the core extraction protection adapter on the outside tube and turn while applying a little pressure, so that it grips into the indents on the flange (in a similar way to the knob when installed). The openings in the adapter and the outside tube web must align.
  • Page 33 6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 33 / 69 IMPORTANT Damage resulting from liquids This product contains electronic and/or mechanic components that may be damaged by liquids of any kind. Keep liquids away from the electronics.  Violent action on the thumb turn Don't strike the thumb turns when installing the cylinder.
  • Page 34 6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 34 / 69 3. Carry out a function test. Cylinder fully installed. 6.3.4.2 Installing the HZ DK cylinder The thumb-turn on .DK and MR cylinders can be removed for special escutcheon covers. Small slotted-head screwdriver ü...
  • Page 35 6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 35 / 69 2. Engage the locking cylinder with an authorised identification medium. 3. Push the thumb-turn into the cylinder body until it locks into position. 4. Hold the thumb-turn down and turn it anti-clockwise until it comes to a stop (hold cam if necessary).
  • Page 36 6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 36 / 69 7. Pull off the existing rings (note order!). 8. Insert the cylinder body through the door from the inside. 9. Affix the cylinder body with the fastening screw.
  • Page 37 6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 37 / 69 10. Fit the escutcheon onto the door. 11. Insert the existing rings and a new plastic ring onto the thumb-turn spindle in the same order. 12. Reinsert the thumb-turn into the cylinder body. 13.
  • Page 38 6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 38 / 69 14. Press the thumb-turn into the cylinder casing and turn it clockwise until it locks into place. 15. Check that the thumb-turn is into place by turning it back and forth. Cylinder fully installed.
  • Page 39 6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 39 / 69 6.3.4.3 Disassembly If you need to disassemble the half cylinder, please proceed as follows: 1. Using a tool such as a screwdriver, grip into the two slots in the plastic disc between the thumb-turn and the profile cylinder housing and turn the tool while applying a little pressure.
  • Page 40: Installing Swiss Round

    6. Installation instructions Locking cylinder (Z4) 3061 (Manual) 40 / 69 This generally also applies when installing the cylinder in a key switch, for example. 6.3.5 Installing Swiss Round Both cylinders and a fitting need to be removed from doors when installing a Swiss round cylinder.
  • Page 41: Audible Signals

     cylinder does not en- zone. None gage. Activated alarm  system while using the SimonsVoss Block Lock. Battery Warning Level 1: Replace batteries in the 8 short audible signals Batteries are low. cylinder. before engaging. Battery Warning Level...
  • Page 42: Battery Warnings

    7. Audible signals Locking cylinder (Z4) 3061 (Manual) 42 / 69 7.1 Battery warnings A battery management system has been implemented in locking cylinders and transponders which warns the user in good time that the battery capacity is diminished. This prevents the batteries from becoming fully discharged.
  • Page 43 7. Audible signals Locking cylinder (Z4) 3061 (Manual) 43 / 69 Emergency battery – Freeze mode  (G2 cylinders): In freeze mode, an audible signal will sound if an attempt is made to open using an authorised transponder, but the cylinder will not engage. The G2 cylinder can now only be opened using a battery replacement transponder or programming device.
  • Page 44: Battery Warning For Transponders

    7. Audible signals Locking cylinder (Z4) 3061 (Manual) 44 / 69 Battery replace- Up to 15,000 ac- Up to 50 access ment: activate cess events or up events or up to with battery re- to 9 months on 30 days placement standby transponder...
  • Page 45: System 3060 Battery Replacement

    Fingerprints on batteries may reduce battery life considerably. Only use batteries which have been approved by SimonsVoss. NOTE You may cause damage to the Locking Cylinder 3061 if you reverse the po- larity.
  • Page 46: Emergency Battery Procedure

    8. System 3060 battery replacement Locking cylinder (Z4) 3061 (Manual) 46 / 69 8.3 Emergency battery procedure As stated above, a locking cylinder changes to storage mode (G1) or freeze mode (G2) if Battery Warning Level 2 is ignored. A different procedure is used each for G1 and G2 to eliminate this mode.
  • Page 47: Procedure

    8. System 3060 battery replacement Locking cylinder (Z4) 3061 (Manual) 47 / 69 NOTE Only use the G2 battery replacement transponder to deactivate freeze mode and then immediately replace the cylinder batteries. Misuse may lead to complete battery discharge and, consequently, a complete failure of the cylinder.
  • Page 48: Procedure For Outer Thumb Turn (Mh Cylinder)

    8. System 3060 battery replacement Locking cylinder (Z4) 3061 (Manual) 48 / 69 8. Insert the new batteries into the holder at the same time with the posit- ive poles next to each other; change the batteries as quickly as possible. Use clean gloves free of fat or grease to handle new batteries.
  • Page 49 8. System 3060 battery replacement Locking cylinder (Z4) 3061 (Manual) 49 / 69 1. Use the battery replacement key to detach the outer thumb-turn. To do so, face the outer thumb-turn and place the battery replacement key on the bayonet mount and turn in a clockwise direction until you can re- move the thumb-turn easily.
  • Page 50: Maintenance, Cleaning And Disinfection

    HZ.SL: It is recommended to grease the latching edge on the electrical en- closure lever handle. Empty batteries always must be replaced by new ones approved for use by SimonsVoss. Dispose of old batteries in the proper manner. Carry out a new functional test after changing the batteries in anti-panic cylinders.
  • Page 51: Areas Of Use

    10. Areas of use Locking cylinder (Z4) 3061 (Manual) 51 / 69 10 Areas of use 10.1 General The digital locking cylinder is compatible with locks for Euro profile cylinder as per DIN 18252 and EN1303. 10.2 Fire doors As a general rule, this cylinder can be fitted into fire doors. However, you must check that it is actually approved for use in fire doors.
  • Page 52: Accessories

    11. Accessories Locking cylinder (Z4) 3061 (Manual) 52 / 69 11 Accessories 11.1 Thumb-turns The following special thumb-turns are available as accessories: Outer thumb-turn in a TN4 design  Outer thumb-turn, 42 mm in diameter with recessed grips  Inside thumb-turn, 36 mm in diameter for a .TS cylinder ...
  • Page 53: Tool

    You can use this tool to install or remove outer thumb-turns and replace batteries. 11.6 Battery set A new set of batteries can be ordered, which contains ten CR2450 batteries. Only ever use batteries approved by SimonsVoss.
  • Page 54: Technical Data

    12. Technical data Locking cylinder (Z4) 3061 (Manual) 54 / 69 12 Technical data Radio emissions 24.50 kHz - 25.06 kHz -20 dBµA/m (10 Only for item m distance) numbers: Z4.*, Z4.*MH* 13.564 MHz - 13.564 MHz -19.57 dBµA/m Only for item (10 m distance) numbers: Z4.*MH*,...
  • Page 55 12. Technical data Locking cylinder (Z4) 3061 (Manual) 55 / 69 Network-ready with integrated LockNode (WN)  LockNode can be retrofitted  Time zone groups: G1: 5 / G2: 100  Max. number of transponders per G1 Cylinder: 8000 / G2: 64,000 ...
  • Page 56: Half Cylinder

    12. Technical data Locking cylinder (Z4) 3061 (Manual) 56 / 69 MS cylinder thumb-turns Outside thumb-turn: identical to Material: standard cylinders; internal thumb- turn: identical to standard cylinders Outside thumb-turn: Cover made of high-gloss brass; recessed grip: matt Colours: brass: internal thumb-turn: Cover made of high-gloss brass;...
  • Page 57: Dimensional Drawings Cylinder

    12. Technical data Locking cylinder (Z4) 3061 (Manual) 57 / 69 LockNode can be retrofitted  Time zone groups: G1: 5 / G2: 100  Max. number of transponders per G1 Cylinder: 8000 / G2: 64,000  Different permanent/open modes ...
  • Page 58 12. Technical data Locking cylinder (Z4) 3061 (Manual) 58 / 69 Comfort - Active (CO) Exterior side Interior side Comfort - Passive (CO MP) Exterior side Interior side Freely rotating - Active (FD) Exterior side Interior side...
  • Page 59 12. Technical data Locking cylinder (Z4) 3061 (Manual) 59 / 69 Freely rotating - Passive/hybrid (FD MP/MH) Exterior side Interior side Half cylinder - Active (HZ) Half Cylinder - Passive (HZ MP)
  • Page 60 12. Technical data Locking cylinder (Z4) 3061 (Manual) 60 / 69 DoorMonitoring - Active (DM) Exterior side Interior side DoorMonitoring half cylinder Active (DM HZ) Anti-panic Freely rotating - Active (AP2 FD) Exterior side Interior side...
  • Page 61 12. Technical data Locking cylinder (Z4) 3061 (Manual) 61 / 69 Anti-panic Free rotating - passive (AP2 FD MP) Exterior side Interior side Anti-panic Reader on both sides - Passive (AP2 BL MP) Exterior side Interior side Scandinavian Oval - Active (SO)
  • Page 62 12. Technical data Locking cylinder (Z4) 3061 (Manual) 62 / 69 Scandinavian Oval - Passive (SO MP) Scandinavian Round - Active (RS) Scandinavian Round - Passive (RS MP) Swiss Round Comfort - Active (SR CO) Exterior side Interior side...
  • Page 63 12. Technical data Locking cylinder (Z4) 3061 (Manual) 63 / 69 Swiss Round Comfort - Passive (SR CO MP) Exterior side Interior side Swiss Round half cylinder - Active (SR HZ) Swiss Round half cylinder - Passive (SR HZ MP)
  • Page 64 12. Technical data Locking cylinder (Z4) 3061 (Manual) 64 / 69 United Kingdom Mortise - Active (UKM) United Kingdom Mortise - Passive (UKM MP) United Kingdom Outer Cylinder - Active (UKR)
  • Page 65 12. Technical data Locking cylinder (Z4) 3061 (Manual) 65 / 69 United Kingdom External Cylinder - Passive (UKR MP)
  • Page 66 Locking cylinder (Z4) 3061 (Manual) 66 / 69 13 Declaration of conformity The company SimonsVoss Technologies GmbH hereby declares that the articles (Z4.*, Z4.*MH*, Z4.*MP*) comply with the following guidelines: 2014/53/EU -RED-  or for the UK: UK statutory 2017 No. 1206 -Radio equipment- 2011/65/EU -RoHS- ...
  • Page 67 Our technical support will be happy to help you (landline, costs depend on provider): +49 (0) 89 / 99 228 333 Email You may prefer to send us an email. support-simonsvoss@allegion.com FAQs You will find information and help in the FAQ section: https://faq.simons-voss.com/otrs/public.pl...
  • Page 68 14. Help and other information Locking cylinder (Z4) 3061 (Manual) 68 / 69 Address SimonsVoss Technologies GmbH Feringastr. 4 D-85774 Unterfoehring Germany...
  • Page 69 Our commercial success lies in the courage to innovate, sustainable thinking and action, and heartfelt appreciation of employees and partners. SimonsVoss is a company in the ALLEGION Group, a globally active network in the security sector. Allegion is represented in around 130 countries worldwide (www.allegion.com).