Command Class Battery, Version 1 - Yale real living Z-Wave Plus YRD642-ZW3 Installation Manual

Smart module
Table of Contents

Advertisement

For Firmware Target 0, the Firmware 0 Version (0x02) and Sub version (0x22)
translate to module firmware decimal value of "2.34".
For Firmware Target 1 (the data under vg1), Firmware Version (0x2C) and Sub
version (0x00) translate to lock firmware decimal value of "4.3.00".

Command Class Battery, Version 1*

* This command class requires security.
Per the Z-Wave Plus ™ Specification, the lock will send a Battery Report with a
value of 0xFF to the Lifeline node when a critical battery level is reached (starting
at about 3.8V for Product Type IDs 0x8002 & 0x8004 and starting at about 4.2V for
Product Type ID 0x8109, 0x810A, 0x8103 & 0x8104). In addition, the Yale Locks
provide 2 earlier low battery alarms through the notification command class (see
Table 7 - Notification Table).
Low battery alarms will be generated if the lock is in a low battery state during one
of the following events: any motor activation (keypad lock/unlock, RF lock/unlock,
etc.), controller sends Get Battery command, or the unsolicited battery report was
triggered. Yale locks will generate an unsolicited Battery Report every 8 hours if a
node is listed in the Lifeline Group.