A�achments
1. Chart for se�ng the detector address
address
1
2
3
1
ON
OFF
OFF
2
OFF
ON
OFF
3
ON
ON
OFF
4
OFF
OFF
ON
5
ON
OFF
ON
6
OFF
ON
ON
7
ON
ON
ON
8
OFF
OFF
OFF
9
ON
OFF
OFF
10
OFF
ON
OFF
11
ON
ON
OFF
12
OFF
OFF
ON
13
ON
OFF
ON
14
OFF
ON
ON
15
ON
ON
ON
16
OFF
OFF
OFF
2. Conversion between volumetric concentra�on and lower explosion limit of methane

3. Table of error codes

code
cause
1
Sensor is not present (EEPROM is not
communica�ng)
2
Unknows sensor type
3
Type 2 sensor type ID not found in the
table se�ng LMP91000
4
CRC does not match these nsor
EEPROM
5
LMP91000 does not respond
6
The set sensor ID does not match with
the connected sensor
7
Reserved
8
EL sensor test error
9
Detector is in prehea�ng mode
10
Reserved
11
reserved
12
Error reading the internal FLASH
13
Error reading the internal FLASH
14
Error reading the internal FLASH
15
Sensor error
16
The device exceeded the maximum
calibra�on interval by 50 %
129
The measured value exceeds the range
of -10 %
130
The result of the AD conver�on is out of
range
4
5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
%DMV – level of lower explosion limit concentra�on in %
%obj
– volume sample of gas
4,4
– lower explosive limit of methane (4.4 % by volume)
1
2
17
ON
OFF
18
OFF
ON
19
ON
ON
20
OFF
OFF
21
ON
OFF
22
OFF
ON
23
ON
ON
24
OFF
OFF
25
ON
OFF
26
OFF
ON
27
ON
ON
28
OFF
OFF
29
ON
OFF
30
OFF
ON
31
ON
ON
32
OFF
OFF
solu�on
Disconnect and reconnect the sensor, then restart
the sensor by disconnec�ng and reconnec�ng the
power
Contact the manufacturer
Contact the manufacturer - FW update required
Sensor error - solve via DEGA Config
Sensor error - contact the manufacturer
Checking the configura�on of the sensor required -
solve via DEGA Config
Reserved
Sensor error
Wait a few minutes, the detector will automa�cally
enter measurement mode
Restart the detector. If the error persists, cont act
the manufacturer
Restart the detector. If the error persists, contact
the manufacturer
Restart the detector. If the error persists, contact
the manufacturer
Re pl a ce the sensor
Calibra�on is neccesarry
If the error persists, re calibra�on required
Recalibra�on required
17
3
4
5
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON