3.5" touchscreen videophone for IPure system
27 mm
A
B
C
Fig. 1 Front
DESCRIPTION
3.5" TFT high-resolution LCD monitor, OSD, capacitive touch
screen, 4 buttons configurable for functions: door open, inter-
com call, auto start, camera switching, timed privacy service.
12Vdc or PoE power supply.
2 inputs / 2 outputs.
Wall mounted, white or black finish.
VIDEOPHONE INITIALISATION
If powering on the videophone (through a PoE switch/router or
an external power supply unit) the display shows the message
"DEVICE NOT INITIALISED", use the configuration software IPure
Wizard to setup the device and the system.
LEDS
Privacy on LED
It illuminates when the privacy service is enabled.
Service LED
It flashes slowly if the gateway is not found.
If turned on, the device has failed to register with the
configured SIP server.
Missed call LED
C
It flashes slowly if there is a missed call.
Art. 6296 - Installation instructions
144 mm
F
D
E
G
H
Fig. 2 Inside
LEGEND
A
Touchscreen display
B
Tactile programmable
buttons and LED's
C
Missed call LED
D
Call tone volume control
E
Brightness control
F
Handset
G
Induction coil for hearing
aid users
To download the programming software
IPure Wizard and obtain the latest firmware
and manuals please visit the following web-
site and register
https://service.videx.it/
The informations contained in this manual are valid
for devices with software version 2.5.0 and later.
CONTROLS
Call tone volume control
3 level switch (it controls also the local bell volume).
Display brightness control
Sliding wheel.
Microphone volume trimmer
It increases the volume from the handset to the door
panel loudspeaker.
- 1 -
I
L
E
D
H
Connection terminals
I
Ethernet connector
L
Microphone volume trimmer
L
66251115 - V5.5 - 31/03/24
Rev.0.1

Advertisement

Table of Contents
loading

Summary of Contents for Videx 6200 Series

  • Page 1 6200 Series Art. 6296 3.5" touchscreen videophone for IPure system Rev.0.1 27 mm 144 mm Fig. 1 Front Fig. 2 Inside DESCRIPTION LEGEND 3.5” TFT high-resolution LCD monitor, OSD, capacitive touch Touchscreen display Connection terminals screen, 4 buttons configurable for functions: door open, inter-...
  • Page 2 6200 Series Art. 6296 3.5" touch screen videophone for IPure system HOME SCREEN The Home screen (Fig. 3) includes navigation buttons, control Date and time Settings Privacy buttons and general information: menu ON/OFF • Settings menu button button button 11:12 Navigate to other screens (for details see “Settings menu”...
  • Page 3 6200 Series Art. 6296 3.5" touch screen videophone for IPure system INTERCOMS Shows the list of indoor stations connected to the device. INTERCOMS Bedroom 1. Tap the intercom you want to call: it will be highlighted in blue. 2. Tap the...
  • Page 4: Settings Menu

    Settings menu. 2. Once you enter the correct password the device shows the QR binding code. 3. Open Videx CloudNected app on your smartphone, login or register (if you are not registered yet). 4. Tap the icon on the top left corner of the app, next tap “Device Manager”...
  • Page 5: Screen Cleaning

    6200 Series Art. 6296 3.5" touch screen videophone for IPure system SET MELODY Enables you to set the ringtone (three tones available): SET MELODY 1. Tap buttons to select the desired ringtone. The device will play the Tyoe current ringtone. 2. Tap the...
  • Page 6: Camera Settings

    6200 Series Art. 6296 3.5" touch screen videophone for IPure system CAMERA SETTINGS Enables you to adjust contrast, brightness and hue for the picture coming CAMERA SETTINGS from any outdoor station: 1. Enter the administrator password and then tap the button.
  • Page 7 • Video preview • Direct call • DTMF RFC2833/SIPINFO • Transport: UDP To enable and configure this feature you must use the latest version of Videx IPure Wizard software. - 7 - Art. 6296 - Installation instructions 66251115 - V5.5 - 31/03/24...
  • Page 8 Wizard software, you can try to restore it by manually putting it into boot mode. It is strongly recommended that this operation is carried out by a qualified engineer and in any case after contact with videx support. • Disconnect the videophone from the power supply (Ethernet connector if sup- plied by PoE or +12Vdc terminal connector if supplied by a power supply unit).
  • Page 9: Technical Specifications

    The four tactile buttons (Fig. 1 ) are fully programmable us- ing the programming software IPure Wizard. CONNECTION TERMINALS SIGNALS TECHNICAL SPECIFICATIONS Housing and mounting: 6200 Series - Surface Display resolution: 320 x 240 pixel Push buttons: Programming: Through touchscreen or PC IPure...
  • Page 10: Internal Web Server

    6200 Series Art. 6296 3.5" touch screen videophone for IPure system INTERNAL WEB SERVER The device has an internal web server accessible via a web browser that allows you to change certain device settings without using the IPure Wizard software. ENABLE/DISABLE WEB SERVER To enable or disable the web server, tick or untick the Enable HTTP Server checkbox in the HTTP section of the IPure Wizard software.
  • Page 11 6200 Series Art. 6296 3.5" touch screen videophone for IPure system HOME Shows the following device information: • ID Cloud configured SIP configured and connected and connected • IP address • MAC address Cloud configured SIP configured • Description but not connected but not connected •...
  • Page 12: Sip Settings

    6200 Series Art. 6296 3.5" touch screen videophone for IPure system Fig. 27 HTTP settings HTTP This section allow you to enable, disable and configure the HTTP server. The HTTP server allows the control of the built-in relays through http commands.
  • Page 13: Event Log

    Fig. 28 Event Log ADVANCED (ADV) Click Reboot Device to reboot the device. Click Put Device In Update Mode to put the device in firm- ware update mode through the software for PC Videx Firmware Updater. Fig. 29 Advanced (Adv.) SERVICES...
  • Page 14: Wall Mounting Instructions

    6200 Series Art. 6296 3.5" touch screen videophone for IPure system WALL MOUNTING INSTRUCTIONS Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 WARNING: Remember to remove the mains before installing the videomonitor. 1. Disconnect the handset, then remove the cover inserting a 5.5mm flat screwdriver into both the clips then rotate clockwise until you listen a “CLICK!”...
  • Page 15 “DEVICE NOT INITIALISED”, utilizzare il software configurato- strarsi sul sito web re IPure Wizard per impostare il dispositivo e il sistema. https://service.videx.it/ Le informazioni contenute in questo manuale sono valide per i dispositivi con software versione 2.5.0 e successive.
  • Page 16: Schermata Home

    Serie 6200 Art. 6296 Videocitofono touchscreen 3,5" per sistema IPure SCHERMATA HOME La schermata Home (Fig. 3) include i pulsati di navigazione, Data e ora Pulsante Pulsante pulsanti di controllo e informazioni generali: Menù ON/OFF • Pulsante Menù impostazioni impostazioni Privacy 11:12 Navigazione verso altre pagine (vedere “Menù...
  • Page 17 Serie 6200 Art. 6296 Videocitofono touchscreen 3,5" per sistema IPure CITOFONI Mostra la lista dei posti interni connessi al dispositivo. CITOFONI Camera 1. Toccare il posto interno che si vuole chiamare: verrà evidenziato in celeste. 2. Toccare il pulsante verde nell’angolo superiore destro dello schermo per Cucina confermare: il dispositivo avvia una chiamata intercomunicante con il po- sto interno selezionato...
  • Page 18: Menù Impostazioni

    • Versione software e hardware Toccare il pulsante per ritornare al Menù impostazioni. COLLEGA APP VIDEX Consente al dispositivo di connettersi all’app per smartphone Videx Cloud- COLLEGA APP VIDEX Nected: Scansionare il codice QR 1. Inserire la password di amministratore e successivamente toccare il pulsante Toccare il pulsante per cancellare le cifre immesse.
  • Page 19 Serie 6200 Art. 6296 Videocitofono touchscreen 3,5" per sistema IPure SUONERIA Consente di impostare la suoneria (tre melodie disponibili): SUONERIA 1. Toccare i pulsanti per selezionare la suoneria desiderata. Il dispositi- Tipo vo emetterà la suoneria corrente. 2. Toccare il pulsante verde per confermare: il dispositivo torna al Menù...
  • Page 20: Impostazioni Videocamera

    Serie 6200 Art. 6296 Videocitofono touchscreen 3,5" per sistema IPure IMPOSTAZIONI VIDEOCAMERA Consente la regolazione di contrasto, luminosità e saturazione dell’immagine IMPOSTAZIONI TELECAMERA proveniente da ogni posto esterno video: 1. Inserire la password di amministratore e successivamente toccare il pulsante 2. Il dispositivo mostra l’elenco dei posti esterni video connessi: toccare uno di essi e successivamente toccare il pulsante 3.
  • Page 21 Serie 6200 Art. 6296 Videocitofono touchscreen 3,5" per sistema IPure ATTIVARE O DISATTIVARE IL MICROFONO CATTURARE UN FOTOGRAMMA RIFIUTARE LA CHIAMATA O CHIUDE- RE LA CONVERSAZIONE 1. Toccare l’icona per disattivare il mi- Di default, in ogni chiamata video o au- crofono.
  • Page 22 Si raccomanda caldamente di far eseguire questa operazione da un ingegne- re qualificato e in ogni caso dopo aver contattato il supporto clienti Videx. • Scollegare il videocitofono dall’alimentazione (sia se il connettore ethernet è ali- mentato in PoE o se il connettore +12Vdc è...
  • Page 23: Specifiche Tecniche

    Serie 6200 Art. 6296 Videocitofono touchscreen 3,5" per sistema IPure IMPOSTAZIONI DEFAULT PULSANTI FISICI PROGRAMMABILI IMPOSTAZIONI DEFAULT INGRESSI Standby In conversazione Standby In conversazione Chiamata di piano Chiamata di piano Disabilitato Disabilitato Chiama Attiva relè 2 del posto esterno Disabilitato corrente Attiva relè...
  • Page 24: Primo Accesso

    Serie 6200 Art. 6296 Videocitofono touchscreen 3,5" per sistema IPure SERVER WEB INTERNO Il dispositivo include un server web integrato accessibile via browser che consente di variare una parte delle impostazioni senza ricorrere al software IPure Wizard. ABILITARE/DISABILITARE IL SERVER WEB Per abilitare o disabilitare il server web, spuntare o togliere la spunta sulla casella Abilita Server HTTP nella sezione HTTP del software IPure Wizard.
  • Page 25 Serie 6200 Art. 6296 Videocitofono touchscreen 3,5" per sistema IPure HOME Mostra le seguenti informazioni del dispositivo: • ID Cloud configurato SIP configurato e connesso e connesso • Indirizzo IP • Indirizzo MAC Cloud configurato SIP configurato • Descrizione e non connesso e non connesso •...
  • Page 26 Serie 6200 Art. 6296 Videocitofono touchscreen 3,5" per sistema IPure Fig. 27 Impostazioni HTTP HTTP Questa sezione permette di abilitare, disabilitare e configurare il server HTTP. Il server HTTP permette di abilitare l’interfacciamento con i relè integrati tramite comandi http. Una volta abilitato come mostrato nell’immagine, se si apre ad esempio il link http://192.168.
  • Page 27 Cliccare Riavvia dispositivo per riavviare il dispositivo. Cliccare Metti il dispositivo in modalità aggiornamento per mettere il dispositivo in modalità di aggiornamento fir- mware (usare il software Videx Firmware Updater). Fig. 29 Avanzate (Adv.) SERVIZI Mostra la lista dei servizi (uscite e ingressi) locali o di altri dispo- sitivi e il loro relativo stato così...
  • Page 28 Serie 6200 Art. 6296 Videocitofono touchscreen 3,5" per sistema IPure WISTRUZIONI DI INSTALLAZIONE A PARETE Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 ATTENZIONE: Ricordarsi di togliere l’alimentazione prima di installare il videocitofono. 1.
  • Page 29 Switch PoE Switch PoE Switch PoE 2505 2505 Rif.SLD_IPURE_V_001 - 29 - 66251115 - V5.5 - 31/03/24...
  • Page 30 - 30 - 66251115 - V5.5 - 31/03/24...
  • Page 31 DISPOSAL In accordance with the Legislative Decree no. 49 of 14 March 2014 “Implementation of the Directive 2012/19/EU on waste electrical and electronic equipment (WEEE)”. The crossed-out bin symbol on the equipment or on the packaging indicates that when the product reaches the end of its lifetime, it must be collected separately from mixed municipal waste.
  • Page 32 APOIO AO CLIENTE ‫خدمة العمالء‬ Portugal office: Singapore office: VX IBÉRIA, UNIPESSOAL LDA VIDEX ASIA PACIFIC PTE LTD Rua Tenente Mário Grilo, 26 D, E, F 31 Woodlands Close 4200-397 Porto #06-37 Woodlands Horizon Phone: (+351) 221 124 531 Singapore 737855 www.videx.it...

This manual is also suitable for:

6296

Table of Contents