M E R C U R Y I G N I T I O N : I N S TA L L AT I O N C O N T I N U E D
6.6 Apply joint compound, thread sealant, or plumbing tape to the threads to the 3/4" end of the ½" x 3/4" reducing
fitting and connect to the bottom of the 3/4" Tee. Tighten with a wrench to avoid leaks. {See Photo 19a and 19b to
see which threads need sealant, and the assembly order}
6.7 A flared fitting is loosely attached to each Flex Line. Remove the flared fitting from the ends of each Flex Line.
6.8 Apply joint compound, thread sealant, or plumbing tape to the threads of the male end of two of the flared
fittings. Connect the male ends to the two sides of the 3/4" Tee. Tighten with a wrench to avoid leaks. {See Photo
19a and 19b to see which threads need sealant, and the assembly order}.
6.9 WITHOUT ANY THREAD SEALANT, take the female flared ends of the flex lines attached to the valve assembly
from Step 4 and attach to the male flared end of each of the flared fittings extending from the 3/4" Tee. Tighten
with a wrench to avoid leaks. {See Photo 20}.
No Joint Compound, Thread
Sealant, or Tape
Photo 20: Connecting the Flex Lines
7. PLACE THE PLATE/PAN WITH THE ATTACHED PILOT ASSEMBLY INTO THE FIRE FEATURE.
8. PUT THE TOP OF PILOT HOOD BACK IN PLACE.
9. REFER TO THE GENERAL INSTALLATION INSTRUCTIONS FOR ALL UNITS ON PAGES 13 - 14 OF THIS
INSTRUCTION MANUAL.
34
Warming-Trends.com | 303 346 2224 | Orders@Warming-Trends.com
Warming_Trends_Instruction_Manual_V3.8.indd 34-35
Warming_Trends_Instruction_Manual_V3.8.indd 34-35
No Joint Compound, Thread
Sealant, or Tape
W A R N I N G L A B E L
The following label has been provided with the appliance. Affix the label in a conspicuous location adjacent to the
appliance.
WARNING: Improper installation, adjustment
alteration, service, or maintenance can cause
property damage, personal injury, or loss of life.
Refer to the owner's user guide provided with
this appliance. Installation and service must
be performed by a qualified installer, service
agency, or the gas supplier.
WARNING: Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliances.
An LP-cylinder not connected for use shall not
be stored in the vicinity of this or any other
M E D I A I N S TA L L AT I O N
Only use approved decorative media (glass, lava rock, ceramic log sets, steel log sets, etc.) that have been
manufactured for specific use in outdoor fire features.
Media must be ½" or larger in size to prevent media from falling into gas orifices and blocking flow of gas out of jets.
Use approved media only. To avoid media dust or debris from getting into the system, do not dump the media over the
burner. Place the media onto the plate or pan.
The appliance is designed to use approved media that is correctly installed over the burner to achieve proper
combustion. Use of any media outside of the approved media may void warranty and affect proper operations.
Burner may be covered by approved media up to 1/2" above the jets. PLEASE NOTE - Covering jets by more than 1/2" of
media may create back pressure and gas leakage resulting in pooling of gas under the fire feature which can result in
explosion which could cause property damage, personal injury, or death.
Media should be piled no more than halfway up the pilot of assembly so that pilot gas orifice opening and the pilot cooling
holes are above the media allowing for pilot flame to easily reach gas jet orifice. Incorrect media installation that blocks
pilot cooling holes will cause the pilot flame to stifle, blocking of thermal sensor and/or a delay in burner ignition. (See
pictures below for examples of proper installation heights.)
For Ceramic Log Sets: Place logs on top of lava rock or media base according to preference and desired flame pattern.
Do not block, cover, or obstruct the pilot assembly. Blocking, covering, or placing ceramic logs too close to the pilot
assembly may cause excessive heat on pilot causing system to fail. This is not covered under warranty.
Example of proper media height on pilot assembly.
Pilot Cooling Hole
Warming-Trends.com | 303 346 2224 | Orders@Warming-Trends.com
AVERTISSEMENT: Une installation, un
ajustement, une modification, une réparation
ou un entretien inapproprié peuvent être la
cause de blessures ou de dommages. Veuillez
lire attentivement les instructions d'installation,
d'utilisation et d'entretien avant d'installer ou de
réparer ce matériel.
AVERTISSEMENT: Ne pas entreposer ni utiliser
de l'essence ni d'autres vapeurs ou liquides
inflammables dans le voisinage de l'appareil, ni
de tout autre appareil.
35
2/20/2024 10:46:39 AM
2/20/2024 10:46:39 AM

Advertisement

Table of Contents
loading

Table of Contents