Commissioning
After turning on your system, follow these steps to configure battery
settings for optimal performance.

Battery Setup

1. Access Battery Setup:
Click on the gear icon in the upper right-hand corner of the system interface
to navigate to the 'Battery Setup' section.
2. Battery Capacity:
Enter your battery storage total capacity in amp-hours (Ah). Example: "400Ah".
Note one Dura5 battery = 100Ah, total capacity = (battery quantity x 100)
3. Maximum Charge/Discharge Current:
• Set 'Max A Charge' to your batteries' maximum charging amperage.
Example: "200A."
• Set 'Max A Discharge' to your batteries' maximum discharging amperage.
Example: "200A."
Battery Configuration and Amperage Table
Battery
KIT W
1
2
3
4
System Amperage Handling:
• For a single set of 4 AWG cables, the system supports a maximum
amperage of 100A; with two sets of 4 AWG, it can handle up to 200A.
• Match inverter settings with the number of cables and batteries for proper
charge/discharge rates. Ensure settings align with the battery/cable
configuration's maximum power output to prevent inefficiency, damage,
or potential danger.
©2024 Power Center
Duracell is a registered trademark of Duracell U.S. Operations, Inc., used under license. All rights reserved.
Manufactured under license and warranty supported by Omega Green Power in San Jose, CA.
KIT G
1 set of cable
80A/4KW
100A/5KW
100A/5KW
100A/5KW
Setup Guide | Commissioning
2 sets of cable
3 sets of cable
160A/8KW
160A/8KW
240A/12KW
200A/10KW
300A/15KW
Max Hybrid 15 kW
Max Hybrid 15 kW
4 sets of cable
320A/16KW