6. TROUBLESHOOTING

Problem
Manual watering is
not possible using
the
button
Watering program is
not being undertaken
(no watering)
Water Control does
not close
GAR_01887-20.960.06_2024-03-01.indb 7
GAR_01887-20.960.06_2024-03-01.indb 7
Possible Cause
LED next to start delay is blinking red 3x:
battery is very low.
Tap is turned off.
Controller is not connected.
Program entry / modification during or
just before the start pulse.
Valve was opened manually previously.
Tap is turned off.
Controller is not connected.
LED next to start delay is blinking red 3x:
battery is very low.
Minimum pressure of 0.5 bar not
available.
Minimum quantity of water drawn is
less than 20 l/h.
Valve soiled.
Remedy
v Insert a new (alkaline) battery.
v Turn the tap on.
v Mount the controller on housing.
v Make program entry / modifi-
cation outside the programmed
start times.
v Avoid possible program over-
laps.
v Turn the tap on.
v Mount the controller on housing.
v Insert a new (alkaline) battery.
v Ensure a pressure of at least
0.5 bar.
v Connect more drip heads.
v Flush in the opposite direction to
the normal flow direction.
7
01.03.24 09:21
01.03.24 09:21