Advertisement
For safety reasons, children and young people under 16 as well as anyone who is not familiar with these operating instructions should not use the product. Persons with reduced physical or mental abilities may use the product only if they are supervised or instructed by a responsible person. Children must be supervised to ensure that they do not play with the product. Never operate the product when you are tired, ill or under the influence of alcohol, drugs or medicine.
Intended use:
The GARDENA Water Control is intended for private use in domestic and hobby gardens, exclusively for outdoor use, to control sprinklers and watering systems. The Water Control can be used for automatic watering during holidays.
The GARDENA Water Control must not be used for industrial purposes or in conjunction with chemicals, foodstuffs, easily flammable and explosive materials.
Read the operator's manual carefully before use and keep for future reference.
Battery:
To ensure the Water Control runs safely, only a 9V alkaline manganese battery (alkaline) type IEC 6LR61 must be used!
In order to stop the Water Control from failing because of a weak battery if you are away for a long time, the battery must be replaced when the battery symbol flashes.
Setting up:
The Water Control may only be set up vertically with the sleeve nut to the top to prevent water penetrating into the battery compartment The minimum water output to ensure that the Water Control functions correctly is 20 – 30 l/h. For example, at least 10 x 2-litre Drip Heads are required to control the Micro-Drip-System.
At high temperatures (over 70°C at the display) the LCD display may extinguish. This does not affect the program in any way. When the computer cools down the LCD display illuminates again.
The max. temperature for the water flow is 40°C.
Avoid tensile strain.
If the control section is removed when the valve is open, the valve remains open until the control section is reattached.
Cardiac arrest!
This product makes an electromagnetic field while it operates. This field may under some conditions interfere with active or passive medical implants. To decrease the risk of conditions that can possibly injure or kill, we recommend persons with medical implants to speak with their physician and the medical implant manufacturer before you operate the product.
Risk of suffocation!
Small parts can be easily swallowed. There is also a risk that the polybag can suffocate toddlers. Keep toddlers away when you assemble the product.
A video of the setting processes is available here:
You can change the settings or move to the next setting by turning the knob. You can confirm the respective input by pressing the rotary knob. Pressing the knob for a minimum of 3 seconds locks or unlocks the display.
If you will be away for long periods of time, please replace the battery when the battery symbol blinks – otherwise the watering system may fail.
Fig. G:
Fig. H:
P1, P2, P3 denote watering schedules. You can save up to 3 independent schedules. Irrigation days must be selected and confirmed individually. The current weekday will be underlined.
By pressing On / Off, schedules can be activated or deactivated individ ually.
Soil Moisture Sensor (Fig. D and I):
After a soil moisture sensor is connected, the word "Sensor" will be displayed – this can take up to 1 minute.
Once the soil is sufficiently moist, a watering operation is interrupted or a schedule is disabled so that it cannot be activated. This does not affect active (manual) watering.
Soil Moisture Sensor, Art.1867 (optionally available)
Connecting the sensor
An operating point must then be defined. This is the soil moisture level at or above which watering is not to be carried out (see GARDENA Soil Moisture Sensor Operating Instructions).
There are 3 levels to choose from.
Soil Moisture Sensor, Art. 1188, (optionally available, models up to 2020)
The soil moisture level at which a watering will not be carried out as per the schedule can be set using the switching point controller on the soil moisture sensor.
Fig. J:
To put into storage:
Disposal: (in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste. It must be disposed of in line with local environmental regulations.
Dispose of the product through or via your municipal recycling collection centre.
Disposal of the battery:
Dispose of the battery only when discharged.
Problem | Possible Cause | Remedy |
No display appears | Battery is inserted incorrectly. | Check the polarity markings match (+ / –). |
Battery is flat. | Insert a new (alkaline) battery. | |
Temperature on the display is higher than 70°C. | Display appears after the temperature has dropped. | |
Display shows ![]() when button is activated | Buttons have been locked. | Press the ![]() button for 3 seconds. |
Manual watering is not possible using the![]() | Low battery is continuously displayed. | Insert a new (alkaline) battery. |
Tap is turned off. | Turn the tap on. | |
Controller is not connected. | Mount the controller on housing. | |
Minimum pressure of 0.5 bar not available. | Ensure a pressure of at least 0.5 bar. | |
Watering program is not being undertaken (no watering) | Program entry / modification during or just before the start pulse. | Make program entry / modification outside the programmed start times. |
Valve was opened manually previously. | Avoid possible program overlaps. | |
Tap is turned off. | Turn the tap on. | |
Soil moisture or rain sensor registers damp. | If dry, check the setting / location of the soil moisture / rain sensor. | |
Controller is not connected. | Mount the controller on housing. | |
Low battery is continuously displayed. | Insert a new (alkaline) battery. | |
Watering program is not being undertaken (no watering) | Minimum pressure of 0.5 bar not available. | Ensure a pressure of at least 0.5 bar. |
Water Control does not close | Minimum quantity of water drawn is less than 20 l/h. | Connect more drip heads. |
Valve soiled. | Flush in the opposite direction to the normal flow direction. |
NOTE: For any other malfunctions please contact the GARDENA service department. Repairs must only be done by GARDENA service departments or specialist dealers approved by GARDENA.
Water Control | Value / Unit |
Min. / max. operating pressure | 0.5 bar / 12 bar |
Operating temperature range | 5°C to 50°C |
Flow medium | Clear fresh water |
Max. liquid temperature | 40°C |
Program- controlled watering sequences per day | 3 |
Program- controlled watering sequences per week | max. 21 |
Watering duration | 3 x 1 min. – 7 hrs 59 min. |
Battery required | 1 x 9V alkaline manganese Typ IEC 6LR61 |
Operating time of the battery | approx. 1 year |
GARDENA Soil Moisture Sensor | Art. 1867 |
GARDENA Anti-theft device | Art. 1815-00.791.00 from the GARDENA Service |
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the Select 1891 and is the answer not in the manual?
Questions and answers