Closing The Automatic Stop Circuit - ABB IRC5 Product Manual

Panel mounted controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

2 Installation and commissioning

2.5.11 Closing the Automatic Stop circuit

2.5.11 Closing the Automatic Stop circuit
Closing the Automatic Stop circuit
The controller is shipped with a default configuration so that the automatic stop
circuit is open and the general/superior stop circuit is bypassed (short-circuited).
The system can only work in manual mode.
To enable the controller without any additional/external safety equipment, connect
the safety circuit. To bypass Automatic stop circuit, 3-pole jumpers are enclosed
in bag 3HAC078549-001 with corresponding instruction 3HAC078652-001. See the
circuit diagram, 3HAC026871-020.
88
© Copyright 2007-2024 ABB. All rights reserved.
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: AB