2.5.16 Connecting a Limit switch override push button

General
The override circuit enables the possibility to jog an axis out of a forbidden (limited)
zone.
Limitations
The switch has to be placed inside the controller to eliminate the risk of electrical
noise.
Required equipment
Equipment
Contact block (2 pcs)
Push button
Connector X23
Wire
Standard toolkit
Circuit diagram
Procedure
The following procedure details how to connect a Limit switch override circuit in
the controller.
1
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: AB
DANGER
The Limit switch override is used to disconnect safety limitations. Make sure the
Limit switch override function is not active longer than absolutely necessary.
If the option SafeMove is implemented, Limit switch override must never be used
at all. The SafeMove safety controller has its own override function.
Note
The parts needs to be ordered separately from ABB and are not part of an option
package.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more in-
formation, see
Electrical safety on page
© Copyright 2007-2024 ABB. All rights reserved.
2 Installation and commissioning
2.5.16 Connecting a Limit switch override push button
Art. no
3SFA 611 610 R1001
1SFA 611 102 R1105
3HAC021085-001
Note/illustration
35.
Note
ABB CW Control
ABB CW Control
Cable AWG 20 Blue
This is detailed in section
Standard toolkit, IRC5 on
page
249.
See
Circuit diagrams on
page
273.
Continues on next page