Next steps
1. Follow the procedure listed in
2. Confirm that the battery is operating properly, by performing the following steps:
a. Enter the System Setup, while booting, by pressing F2.
b. Enter the correct time and date in the System Setup Time and Date fields.
c. Exit the System Setup.
d. To test the newly installed battery, remove the system from the enclosure for at least an hour.
e. Reinstall the system into the enclosure after an hour.
f. Enter the System Setup and if the time and date are still incorrect, see

Intrusion switch

This is a service technician replaceable part only.

Removing the intrusion switch

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in
Steps
1. Disconnect the intrusion switch cable from the connector on the system board.
2. Slide and push the intrusion switch out of the intrusion switch slot on the system.
Figure 52. Removing the intrusion switch
Next steps
Replace the intrusion
switch.