reliable, error-free data communication, new and pre-existing communication paths
should be verified for TIA/EIA-568-A compliance.
The following table summarizes the relevant cabling standards:
Category
Follow these recommendations for copper data cabling in high electrical noise
environments:
RUGGEDCOM RX1510
Equipment Manual, 10/2023, C79000-G8976-1055-25
1.5.2 Gigabit Ethernet 1000Base-TX Cabling Recommendations
Cabling
1000Base-
TX Compliant
< 5
No
5
Yes
5e
Yes
6
Yes
> 6
Yes
Data cable lengths should be as short as possible, preferably 3 m (10
ft) in length. Copper data cables should not be used for inter-building
communications.
Power and data cables should not be run in parallel for long distances, and
should be installed in separate conduits. Power and data cables should intersect
at 90° angles when necessary to reduce inductive coupling.
Required Action
New wiring infrastructure required.
Verify TIA/EIA-568-A compliance.
No action required. New installations should be designed with
Category 5e or higher.
No action required.
Connector and wiring standards to be determined.
Introduction