Failsafe Relay Specifications; Operating Environment; Mechanical Specifications; Dimension Drawings - Siemens SIMATIC NET RUGGEDCOM RX1510 Equipment Manual

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1510:
Table of Contents

Advertisement

Technical Specifications
5.4 Failsafe Relay Specifications
5.4

Failsafe Relay Specifications

Maximum Switching Voltage
a
Inductive load R/L = 7 ms
b
Resistive load
5.5

Operating Environment

The RUGGEDCOM RX1510 is rated to operate under the following environmental
conditions.
Note
Temperature limits for select line modules may differ from that which can be
withstood by the RUGGEDCOM RX1510. Make sure the selected modules are
rated for the expected environmental conditions before deployment. For more
information, refer to the "RUGGEDCOM RX1510 Series Modules Catalog".
Ambient Operating
Temperature
Ambient Storage Temperature
Ambient Relative Humidity
Maximum Altitude
a
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
b
Operating temperature may vary based on the limitations of installed SFPs. Refer to the "RUGGEDCOM SFP Transceivers Catalog" for
SFP temperature ratings.
c
Non-condensing.
5.6

Mechanical Specifications

Weight
Ingress Protection
Enclosure
5.7

Dimension Drawings

Note
All dimensions are in millimeters, unless otherwise stated.
36
30 VDC
125 VDC
250 VAC
-40 to 85 °C (-40 to 185 °F)
ab
-40 to 85 °C (-40 to 185 °F)
c
5% to 95%
2000 m (6562 ft)
Approximately 5.0 kg (11 lb)
IP30
Aluminum
Rated Switching Current
5 A
a
b
0.1 A
, 0.15 A
6.25 A
Isolation
2800 VDC for 1 minute
between coil and contacts
RUGGEDCOM RX1510
Equipment Manual, 10/2023, C79000-G8976-1055-25