Setting The Charge Clearance Periods - Olsberg CTSC Installation Manual

Standard heater
Hide thumbs Also See for CTSC:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 24

Setting the charge clearance periods

In order to define the clearance periods (off-peak rate) laid down by your electricity supply company, the DIP
switches on the CTSC control unit must be set as described in Table 1. The black field illustrates the position of the
DIP switch.
Model
ON
00
OFF
ON
01
OFF
ON
02
OFF
ON
03
OFF
04
ON
OFF
05
ON
OFF
06
ON
OFF
ON
07
OFF
08
ON
OFF
ON
09
OFF
ON
10
OFF
ON
11
OFF
ON
12
OFF
ON
13
OFF
14
ON
OFF
15
ON
OFF
Table 1
DIP switch position
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Charge OFF peak period
9h from 21:00 until 06:00, reverse
7h from 22:00 until 05:00, reverse
7h from 22:00 until 05:00, forward
8h from 22:00 until 06:00, reverse
9h from 22:00 until 07:00, reverse
14h from 22:00 until 12:00, reverse
8h from 23:00 until 07:00, reverse
9h from 23:00 until 08:00, reverse
8h from 24:00 until 08:00, reverse
7h from 05:00 until 12:00, forward
8+2h from 22:00 until 06:00, reverse
and from 14:00 until 16:00, forward
8+3h from 22:00 until 06:00, reverse
and from 14:00 until 17:00, forward
8+4h from 22:00 until 06:00, reverse
and from 14:00 until 18:00, forward
6+2h from 02:00 until 08:00, reverse
and from 15:30 until 17:30, forward
9h from 21:00 until 06:00, reverse
and 24h from 00:00 until 24:00 (only Sa + Su) forward
9h from 22:00 until 07:00, reverse
and 24h from 00:00 until 24:00 (only Sa + Su) forward
35

Advertisement

Table of Contents
loading

Table of Contents