Accessories; Charge Control; Room Thermostat; Thermal Switching Relay - Olsberg 14/512 Instruction Manual

Standard heater
Table of Contents

Advertisement

Available languages

Available languages

Accessories

Charge Control

The charge control registers the outside temperature
and converts this value into a control current. This
current is passed via the control wires A1/Z1 and
A2/Z2 to the control resistance in each storage heater.
At the same time, the temperature in the heater core
is also registered. The switch-off point of the charge
thermostat is therefore determined by both the outside
temperature and the temperature of the heater core.
In this way, a control of charge according to the out-
side temperature and the residual heat in the heater is
achieved, thus complying with Energy Saving Legisla-
tion.
The control wires can be run together with cable feeds
L, N and PE.
Please also read the Instruction Leaflet supplied with
the Charge Control.

Room Thermostat

The discharge of the storage heaters and thus the
regulation of the room temperature is achieved using
a room thermostat.
The type of thermostat and its configuration is de-
pendent on the heater installation and the require-
ments of the user.
Please also read the Instruction Leaflet supplied with
the Room Thermostat.
Integral Room Thermostat
The integral thermostat is designed for direct mount-
ing to the heater itself:
• Thermo-mechanical room thermostat:
This type of thermostat switches the heater fan ON
or OFF, according to the temperature required.
• Electronic room thermostat:
The speed of the fan is regulated electronically ac-
cording to the required room temperature.
External Room Thermostat
Following thermostats can be supplied:
• Standard Version
- with illuminated ON/OFF switch
• Comfort- Version
- with DAE switch
- and ON/OFF switch

Thermal Switching Relay

By installing a thermal switching relay into each stor-
age heater, the Utility relays in the junction box can be
omitted. The thermal relay uses a bimetal strip and
can be classified as a low-noise switch.
Make certain that the installation of a thermal relay
does not violate installation Codes of Practice of your
local Utility.
Please also read the Instruction Leaflet supplied with
the Thermal Switching Relay.

Day-acting Element

Using the day-acting element the heater can give off
warmth immediately even if it is not charged at all.
The day-acting element works on the ON-PEAK Tariff.
Switching and control of the Day-acting Element is to
be carried out using an integral or external room
thermostat suitable for this purpose.
Please also read the Instruction Leaflet supplied with
the Day-acting Element.

Floor-Standing Consoles

OLSBERG Standard heaters can be mounted on
floor-standing consoles.
The height of the consoles is 100mm.
Please also read the Instruction Leaflet supplied with
the Floor-Standing Consoles.

OTC - Olsberg Tele-Control

The remote control for houses, holiday homes or
apartments with or without a fixed-network telephone
connection.
Please also read the Instruction Leaflet supplied with
the Olsberg Tele-Control.

Further Accessories

Further accessories such as Ceramic Tile Cladding
etc. are available on demand. Contact your local
dealer.
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

14/51414/51314/51514/51714/516

Table of Contents